C&S MCCB , Moulded Case Circuit Breakers - Winbreak2
RANGE : Rating: 16A~1600A , Poles: 3P & 4P.

Moulded Case Circuit Breakers - Winbreak
RANGE: Rating: 15A ~ 1200A , Poles: 2P, 3P & 4P

Moulded Case Circuit Breakers - WiNbreak1
RANGE : Rating: 16A ~ 400A in 3P & 4P
Rating: 16A ~ 200A in single pole

Price and Minimum Quantity

Price: $41
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: C&s Mccb

VERIFIED
Jun-19-21
 
ALSTOM GBCDG61EG018SGCH
IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S
Technical specification
Relay model no CDG61EG018SGCH
Relay type CDG 61
Case size 3D H 30T
Application 2 O/C & 1 E/F
Current setting - O/C 0.5 to 2 amps
Contacts 3 N/O S/R
Output contacts 2 N/O S/R
C.T.Secondary 1 amps
Frequency 50 Hz
Tap Std
Burden / D.M.T 3 VA / 3 Secs
Current setting - E/F 0.2 to 0.8 amps
High set - O/C Setting 4 to 16 amps
High set - E/F Setting 2 to 8 amps
High set/High set contact CAG 13 / 2 N/O S/R
Name plate RFG9126 902
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-19-21
 
ALSTOM GBCDG61EG020SGCH
IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S
Technical specification
Relay model no CDG61EG020SGCH
Relay type CDG 61
Case size 3D HOR.
Application 2 O/C & 1 E/F
Current setting - O/C 0.5 to 2 amps
Contacts 3M S/R
Output contacts 2M S/R
C.T.Secondary 1 amps
Frequency 50 Hz
Burden 3 VA
Operating time 3 secs
Current setting - E/F 0.1 to 0.4 amps
High set - O/C Setting 4 to 16 amps
High set - E/F Setting 1 to 4 amps
High set/High set contact CAG 13 / 2M S/R
Name plate RFG9126 901
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-19-21
Supplier From Anand, Gujarat, India
 
ALSTOM GBCDG61EG040SGCH
IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S
Relay Technical specification
Relay model no CDG61EG040SGCH
Relay type CDG 61
Case size 3D HOR.
Application 2 O/C & 1 E/F
Current setting - O/C 2.5 to 10 amps
Aux.Contacts With Flag 3M S/R
Output contacts 2M S/R
C.T.Secondary 5 amps
Frequency 50 Hz
Burden 3 VA
Operating time 1.3 secs
Current setting - E/F 0.5 to 2 amps
High set - O/C Setting 20 to 80 amps
High set - E/F Setting 5 to 20 amps
High set conts.With flag CAG 13 / 2M S/R
Name plate RFG9125 903
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-19-21
Supplier From Anand, Gujarat, India
 
ALSTOM GBCDG61EG041SGCH
IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S
Technical specification
Relay model no CDG61EG041SGCH
Relay type CDG 61
Case size 3D H 30T
Application 2 O/C & 1 E/F
Current setting - O/C 2.5 to 10 amps
Contacts / Output contacts 3M S/R / 2M S/R
C.T.Secondary 5 amps
Frequency 50 Hz
Burden 3 VA
Operating time 3 secs
Current setting - E/F 0.5 to 2 amps
High set - O/C Setting 20 to 80 amps
High set - E/F Setting 5 to 20 amps
High set CAG 13
Name plate RFG9126 903
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SACH
NON DIR.SELF POWER 3 O/C RELAY 2M S/R
TECHNICAL SPECIFICATION
Model No : CDG31EG002SACH
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C OR O/V SETTING - 0.5 - 2 Amps.
Name Plate RFG9126771
Outline Diagram MFJ014
Wiring Diagram MADZ802-63-1
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31FF002SACH
NON DIR.SELF POWER 3 O/C RELAY 2M S/R
Model No : CDG31FF002SA(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate RFG9126671
Outline Diagram MFJ013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-19-21
 
GBCDG61EG011SGCH
IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI
Technical specification
Relay model no CDG61EG011SGCH
Relay type CDG 61
Case size 3D HOR.
Application 2 O/C & 1 E/F
Current setting - O/C 2.5 to 10 amps
Contacts 3M S/R
Output contacts 2M S/R
C.T.Secondary 5 amps
Taps / Frequency STD / 50 Hz
Burden 3 VA
Operating time 3 secs
Flag Yes
Current setting - E/F 1 to 4 amps
High set - O/C Setting 20 to 80 amps
High set - E/F Setting 10 to 40 amps
High set/High set contact CAG 13 / 2M S/R
Name plate RFG9126 904
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-24-21
Supplier From Anand, Gujarat, India
 
Gbcdg61eg101zmch
Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi
Model No : Cdg61eg101zm(M)
Cdg61/cag17(Mrk-iii)
Application - 3 O/c
Burden / D.m.t - 3 Va / 3 Sec.
C.t. Secondary - 5 Amp C.t.
Case Size - 3d Horz.
Contacts (S/r or H/r) - 2 N/o S/r
Flag - Yes
Frequency - 50 Hz
High Set Type - Cag17
Highset Contacts - 2m S/r
Highset O/c Setting - 12.5 - 100 Amps.
Mounting - Flush
O/c Setting - 2.5 - 10 Amps.
Name Plate - Rfg9126 774
Outline Diagram - Mfj 014
Wiring Diagram - Madz821.31
VERIFIED
Jun-24-21
Supplier From Anand, Gujarat, India
 
GBCDG61EG102ZMCH
IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI
Model No : CDG61EG102ZMCH
CDG61/CAG17(MRK-III)
APPLICATION - 3 O/C
BURDEN - 3 VA
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
D.M.T - 3 SEC.
FLAG - YES
FREQUENCY - 50 HZ
HIGH SET TYPE - CAG17
HIGHSET CONTACTS - 2M S/R
HIGHSET O/C SETTING - 2.5 - 20 Amps.
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate RFG9126 771
Outline drawing MFJ 014
Wiring Diagram MADZ821.31

Verification Status