Power Transmission Steel Towers are used for electrical transmission and distribution. It is set up outdoor, including many types for 110-500 KV electricity transmission lines.

Price and Minimum Quantity

Price: $1.52
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Electrical Transmission Steel Tower

GOLD Member
Oct-16-24
Buyer From Grossmehring, Germany, Croatia
Mar-29-23
 
OMSE project team can carry out all kinds of energy transmission line tower design and, if requested, type tests of these structures are made at international and accredited stations. Besides, static controls of designs from customers and end-users, manufacturing drawings and manufacturing cards can be prepared by the OMSE project team.

All the products that have not been manufactured before, prototype installation and then prototype controls are carried out by OMSE quality teams. After all the details have been examined If it is required, revisions are made, and serial manufacturing phase is initiated. If requested, our customers and end-user management authorities can participate in prototype inspections.
May-05-25

Power Transmission Towers, A

$50 - $50.00K / Ton (UK) (CIF)
MOQ: Not Specified
Supplier From Kagithane, Istanbul, Turkey
 
1-Lattice Towers
Lattice towers are the most common type of transmission towers, consisting of steel frames that form a triangular or square shape. They are strong, flexible, and easy to assemble and transport. Lattice towers can support multiple circuits and span long distances, making them suitable for most terrains and weather conditions. However, they also have some drawbacks, such as high maintenance costs, visual impact, and susceptibility to corrosion and bird collisions.

2-Tubular Towers
Tubular towers are made of hollow steel tubes that are welded or bolted together. They are more compact, aesthetic, and resistant to corrosion than lattice towers, but they are also more expensive, heavier, and harder to transport and install. Tubular towers can support single or double circuits and are often used in urban areas, where space is limited and visual appeal is important. They can also be designed to have different shapes, such as monopoles, H-frames, or delta configurations.
Feb-13-08

Transmission Lattice Tower

$1.00K - $1.60K
MOQ: Not Specified
 
The towers are formulated to house a variety of accessories which include platforms, ladder ear, step bolts, safety cage and so on. Our latticed tower can be used in these fields such as electric power transmission line tower, telecommunication tower, broadcasting tower, watching tower, microwave tower, mapping tower, communication tower, crossing-river tower and other applications.


Model No: 4 Legged Angular Tower(3 Legged Angular Tower or Based on the customerí»s requirements.)
Material: All the steel are used the noted Chinese steel plant products or based on the customers specific requirements or product them according to our Chinese national standard.
Capacity: 60,000tons/year
HS Code: 73081000
Payment Term:T/T; L/C
Port of Loading:Qingdao Port
Aug-10-12
 
The busway is used for the electricity transmission from the electric power transformer to the main distribution screen or from the main distribution screen with a current transmission capacity of 3000a.


Product details
VERIFIED
Jul-27-23
 
Transformers
Feb-18-22
 
Thermal Power COIL Z6206060
is a professional commitment to the generator sets of spare parts, parts of the high-tech companies. provide the best quality valves, the characteristics of flexible movements, the role of reliable, work shock and vibration, Noise, long life, has been the majority of manufacturers of praise and praise.

provides multiple types of spare parts and equipments for power plant :
#DF-COIL Z6206060-DF
pump vacuum P-2332
pt100 thermocouple TC03A2-KY-2B/S3
Diatomite Filter
screw pump diagram ACF090N4
industrial centrifugal pump SDH200-150-315
type k thermocouple WREK2-230
Gate valve Z961H-64
pressure hose SMS-10/N1/4-1524mm-C
thermocouple replacement WREX-001
k-type thermocouple TE-204
coupling types 100LY-215-2
Flow Switch BH-054011-054
pt100 thermocouple WRN2-0301T
high temperature thermocouple TC03A2-KY-2B/S11
EH oil feeder
transfer oil pump DLZB820-R65-3
Thermocouple Assemblies WRN-330MSV2 trip solenoid valve 10YVSTUD M24X130
pumps parts hydraulic 125LY-23
fuel pump 3GR70Ã??2W21
dc screw pump HSNH210-54
Elbow YZD25LG-7-59
ksb pump centrifugal DFB80-80-220-03
thermocouple cable TE-106
high temperature thermocouple TE-305
Precision transient speed instrument / rotational speed sensor DF9011 Pro
vacuum pump 229v PVH74QIC-RSM-IS-10-C25-31
thermocouple k-type temperature sensor WREKD2-04
piston hydraulic pump PVH074R01AB10A2500000001E010A
Type K Thermocouple Cartridge WRN-230
hydraulic screw pump HSNH940-46
Solenoid valve CS-2
screw pump stainless DLZB820-R64A-3
thermocouple protection tube TE-105
multi stage centrifugal pump YCZ50-250B
COIL Z6206060

flexible shaft coupling 125LY 23-4
Signal converter ADAM4520 RS485
vaccum pump P-1278
Oil Filter Element "H10XL-A00-0- M
EH oil pump PVH098R
piston vacuum pump PVH074R01AA10A250000002001AB
vacuum pump compressor P-2402
high temperature thermocouple W08B0691A
SENSOR, TEMPERATURE WRN2-239
pressure hose SMS-15/20-305mm-B
electric pump for lubrication LDX168-36
rotary vane vacuum pump F3-V10-IS6S-1C-20
magnetic coupling centrifugal pump YCZ50-250A
pump screw NM031BY01L06B
thermistor TE-110
thermowell WRKT2-11
Hydrogen supply solenoid valve BZBSF
gear oil transfer pump SDH65-40-200A
piston pump parts MCY14-1B
high pressure piston pump PVH074R01AA(AB)10A250000002001AB0
multistage centrifugal pumps DFB125-80-250-03
thermocouple digital WRNN2-4325
vacuum pump price P-1931A
Gasket 0.8mm
Mechanical Seal 108U-45
COIL Z6206060

DFYL-2022-2-17-ZYR
Feb-08-06
 
Low, medium and high voltage transformers

110kV Class Power Transformers
General
The110kV class low loss transformers are developed by Huapengour workshop through years of service experience and careful analysis of the advantages and disadvantages of the transformers of different manufacturers, both domestic and abroad, and are featured by low loss, low partial discharge, low noise, high strength against short circuit, and high reliability in service. Its outstanding performance has won high reputation throughout China, and the world, and are highly appreciated by experts of the circle. Transformers can be made with welded tank cover and/or flange , Thus obviated from the necessity of lifting out the active part for inspection after arrival on site.
Partial discharge level:
apparent discharge < 80pC at 1.5 times rated voltage.
Noise level :
below 58 dB for transformers 63MVA and below with AN cooling
Losses:
no-load loss 30% lower than specified by GB/T 6451-1995
Reliability:
no damage or oil leakage have been found in transformers in service up to the present
Short-circuit withstand capability:
Our SZ9-31500/110,SSZ-50000/110 transformers successfully passed short-circuit test in National Transformer Quality Inspecting and Testing Center, and in CESI Laboratory of Italy.
Winding
1. Partially interleaved continuous winding is used for HV winding to improve its behavior under lightning impulse, because of its more uniform voltage distribution.
2. All the spacers and vertical strips are rounded at corners, in order to obtain a more reliable insulation structure.
3. Zig-Zag directional flow is provided inside the windings, so that all parts of the windings are better cooled, resulting in lower winding temperature rise, and specifically lower hot-spot temperature, thus the insulation life of the transformer is prolonged.
4. Separate regulating windings are provided for both the 110kV high voltage and the 35kV medium voltage side, so that a more balanced ampere-turn is obtained in spite of tap-changing, the short-circuit withstand capability is thus promoted. Radially, the windings of a phase assembly are tight-fit, little space is left between the core and the low-voltage cylinder, and between the windings. All the vertical strips and cylinders are thoroughly dried before assembly, so that a tight phase assembly can be finally obtained.
Core
1. High permeability grain oriented high quality cold-rolled sheets are used for the fabrication of core. The sheets are cut on automatic cutting line made by Georg Co. of Germany or Soenen Co. of Belgium. The burrs are controlled within 0.02mm.
2. The core is stacked without stacking the upper yoke, the upper yoke sheets are placed into position after the winding blocks are mounted on the core. The joints of the core sheets are mitred 45fpjoint with step-lap. The stacked core is pressed under even pressure and the edge of the sheets are painted with epoxy resin, so that a straight, robust, integral structure is obtained, helping to reduce core loss and noise.
3. Wooden strips are driven into the space between core and LV cylinder. The yoke is kept tightened by epoxy-resin impregnated glass tape, while the lower yoke is pressed against the wall of the lower tank through threaded bolts. The active part of the transformer is in addition kept in position by devices at three places between the upper yoke and the tank cover in such a way that the active part cannot be displaced during transportation.

Verification Status