Model 132-010 consists of Robocon Valve (Balem 130) and Pressure Reducing Pilot valve. It automatically reduces and maintains constant pre-set low pressure according to flow rate change and/or inlet pressure change.
Combining with accurately designed pilot valve and features of the Robocon Valve (BALEM 130), operates diaphragm in chamber due to change downstream pressure controls opening of Basic Valve to maintain constant downstream pressure.
Double chamber structure minimizes the effect of the valve action due to turbulence in the valve and easy to install and maintain.
Automatic Control Valve, Dual Setting Pressure Reducing Valve.
Proportional Pressure Reducing Valve Work by Flow Rate (Model 132-090) controls pressure proportionally according as rate of flow. When rate of flow increase in pipeline, the valve operate higher pressure. When rate of flow decrease , the valve operate lower pressure. Therefore, Model 132-090 controls outlet-pressure proportionally according as rate of flow, even if the rate of flow change arbitrarily or slightly.
Model 132-090 is optimized in waterworks, in state of smooth pressure change in pipeline. Also 132-090 have the function to prevent hunting itself.