Please click here to check who's online and chat with them.

Fluorescence Quantitative Pcr Instrument

Supplier From China
Feb-02-21

Super long life refrigeration sheet modified by special process;
Precision temperature control technology ensures that the temperature fluctuation of each hole is less than 0.1 ;
Ultra high sensitivity PMT system combined with precision optical system ensures accuracy;
New automatic hot cover technology can effectively prevent reagent evaporation;
Maximum 6 channels fluorescence detection, no cross interference between channels;
Intelligent operating system, flexible program setting, comprehensive analysis and report function;

Price and Minimum Quantity

Price: $15000
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Fluorescence Quantitative Pcr Instrument

Sep-16-22

Real Time Pcr Instrument-- Qantgene

$20.00K
MOQ: Not Specified
Supplier From Frankfurt am Main, Germany
 
Real time PCR instrument.
With 16-, 48-, or 96- wells.
with 4-. 5-. or 6- channels.
Oct-11-22
 
CFX Opus 96 Real-Time PCR Instrument 0.2 mL, 96 Wells

Product Details:
Brand BioRad
Model Name/Number CFX Opus 96
Sample Capacity/Format 96 wells
Multiplex analysis Up to 5 targets per well
Dimensions (W x D x H), cm/in 33x56x36 / 13x22x14
Cat No 12011319
Description
CFX Opus is the newest real-time PCR system in our robust CFX Family. The CFX Opus 96 Real-Time PCR System can analyze 96 wells and offers a number of new features:

More uniform thermal performance
Expanded connectivity Wi-Fi, ethernet, and USB
Cloud connectivity: Operate CFX Opus on our BR.io cloud platform or with desktop CFX Maestro Software
Network storage drive access for excellent data management
Shuttle optical system yields consistent optical measurements across your sample plate
SpecificationsThermal CyclerMaximum ramp rate, C/sec5Average ramp rate, C/sec3.3Heating and cooling methodPeltierLid, C30 110 Temperature Range, C4 100Accuracy, C ±0.2 of programmed target at 90 C Uniformity, C ±0.3 well-to-well after 10 sec of arrival at targetGradientOperational range, C30 100Programmable span, C1 24Optical DetectionExcitation6 filtered LEDs Detection6 filtered photodiodes Range of excitation wavelengths, nm450 684 Range of emission wavelengths, nm510 730Sensitivity
Detects 1 copy of target sequence in human genomic DNADynamic range10 orders of magnitudeScan TimeAll channels, sec12
FAM/SYBR Green only, sec3SoftwareOperating systemWindows 10Multiplex analysisUp to 5 targets per wellSystemSample capacity, wells96
Sample size, µl150 (10 50 recommended)
Communication interface USB 2.0
Electrical approvalsIEC, CE Dimensions (W x D x H), cm/in33x56x36 / 13x22x14Weight, kg/lb22/48
VERIFIED
Feb-16-22
 
The COVID-19 RT-PCR Detection Kit is a real-time RT-PCR test intended for the qualitative detection of nucleic acid from the SARS-CoV-2 in upper and lower respiratory specimens (such as anterior nasal swabs, mid-turbinate nasal swabs, nasopharyngeal swabs, oropharyngeal swabs, sputum, lower respiratory tract aspirates, bronchoalveolar lavage, and nasopharyngeal wash/aspirate or nasal
aspirate) from individuals suspected of COVID-19 by their healthcare provider. Testing is limited to laboratories certified under the Clinical Laboratory Improvement Amendments (CLIA) of 1988, 42 U.S.C.
263a, to perform high complexity tests.
Results are for the identification of SARS-CoV-2 RNA. The SARS-CoV-2 RNA is generally detectable in upper and lower respiratory specimens during the acute phase of infection. Positive results are indicative of the presence of SARS-CoV-2 RNA; clinical correlation with patient history and other diagnostic information is necessary to determine patient infective status. The agent detected may not be
the definite cause of disease. Positive results do not rule out bacterial co-infection with other viruses.
Laboratories within the United States and its territories are required to report all positive results to the appropriate public health authorities.
Negative results do not preclude SARS-CoV-2 infection and should not be used as the sole basis for patient management decisions. Negative results must be combined with clinical observations, patient history, and epidemiological information.
The COVID-19 RT-PCR Detection Kit is intended for use by qualified trained clinical laboratory personnel specifically instructed and trained in the techniques of real-time PCR and in vitro diagnostic procedures. The COVID-19 RT-PCR Detection Kit is only for use under the Food and Drug Administration's Emergency Use Authorization.

PRINCIPLE OF DETECTION
This product is a fluorescent probe-based Taqman RT-PCR assay system. Firstly, the RNA of SARS-CoV-2 will be reverse transcribed into cDNA by reverse transcriptase, and then PCR amplification will be performed with cDNA as template. During amplification of the template, the TaqMan probe will
be degraded due to the 5'-3 polymerase activity and exonuclease activity of Taq DNA polymerase, then the separation of fluorescent reporter and quencher enables the fluorescent signal to be detected by instrument. The ORF1ab gene of SARS-CoV-2 will be detected qualitatively by FAM channel, the N
gene of SARS-CoV-2 will be detected qualitatively by JOE channel, the E gene of SARS-CoV-2 will be detected qualitatively by ROX channel, and the internal reference will be detected by CY5 channel.
dUTP and UNG enzyme are used in the kit to prevent contamination of the amplified products.
Internal reference is used in the kit for quality control starting from sample collection
Apr-28-23
Supplier From Qingdao, China
Nov-04-21
Supplier From Suzhou, Jiangsu, China
Jan-31-20
Supplier From Montclair, Ca, United States
May-11-16
Supplier From Ankara, Turkey
Aug-15-20
Supplier From Guangzhou, Guangdong, Singapore
 
This kit is used to qualitatively detect in vitro suspected cases of pneumonitis infected by a new type of coronavirus. The PCR reaction solution contains 2 sets of specific primers and fluorescent probes for specific detection of targets, and an additional set of specific primers and fluorescent probes is used as the internal standard control of the kit for detecting endogenous housekeeping genes.
Lowest detection line:200copy/mL
Specificity: this kit has no cross-reaction with hepatitis B virus, hepatitis C virus, staphylococcus aureus, gram-positive bacteria, shigella bacillus, influenza A, influenza B, enterovirus and human genome DNA/RNA.
Precision reference products: After repeated 20 times, the amplified Ct CV of each fluorescence channel was no more than 5%.Ct CV 5%
Jun-04-21

96 Real-Time Pcr System

$4
MOQ: Not Specified
Supplier From Kowloon, HK, Hong Kong
 
!!!!!!!!!!Buy 40000 Test will free one machine !!!!!!!!

Economical

Practical

Stable and accurate heating and temperature control system

Excellent optical system

Powerful comprehensive performance

Capacity
96x 0.2ml tubes (low profile and standard)

slides tube,

1x 96-well microplate

Dynamic range 1~1010 Copies
Applied probe
1st channel: FAM/ SYBR-Green

2nd channel: HEX, JOE, VIC, TET

3rd channel: ROX Texas -Red

4th channel: CY5

Test method four-fold fluorescence detection
Thermal cycle temperature control semiconductor thermoelectric module
Temperature Range 4.0�°C - 99.0�°C
Heating and cooling Rate â?¥1.5�°C/sec
Thermal Accuracy â?¤0.5�°C (at 90�°C)
Thermal Uniformity â?¤0.5�°C (at 90�°C)
Hot cover temperature range 50�°C - 108�°C
Optical detection excitation wavelength 300-800nm
Detection wavelength 500-800nm
Fluorescence repeatability CVâ?¤ 3%
Fluorescent linearity râ?¥0.99 coefficient of correlation
Software application genotyping by qualitative, absolute quantitative, standard solution curve, relative quantitative and endpoint method
Scanning method full plate, specified rank scanning
Data export format Excel, CVS
Custom report form support
The operating system Window 7/8/8.1/10
Minimum computer configuration Intel or AMD Dual-2.8GHz, more than 4G memory and 128GB
Power Supply AC 220V~, 50Hz, <800VA
Communication Ports RS232, USB
Size 490mmX355mmX284mm
Weight 20Kg

Verification Status