For main power supply&control part
Rated voltage range: 220-240v-50hz
Rated power input: 15w
Output rated voltage: DC 0-18V
Output current: 1.0A
For handpiece(motor) part:
Working voltage: DC 0-18V
Rated current: 1.0A
No load speed: 2900-3000rpm
Load speed: 27000-28000rpm
Instructions:
Don't change the turning directions too frequently, otherwise it will damage the grinding head.
Turn the SPEED CONTROL counterclockwise to decelerate the grinding head to the minimum before turning off and switch the main power source to 0.
After operation, put the grinding head on the top of the main panel.
While the grinding head is in operation, never pull out the 5-pin plug of the portable grinding head.
For long idle time, please disconnect the source power.
Any unauthorized disassembling of the prohibited. In case of any breakdown, please contact the agent or authorized repair center, we promise swift, high-quality and satisfactory service.
If the supply cord if damaged, it must be replaced by the manufacturer, its service agent or similarly persons in order avoid a hazard.
The apparatus is not ready for the physically weak, slow response or a mental disorder of persons(including children) to use, except in the security responsibility of the guidance or assistance.
Vacuum aspirator for fat grafting,use with syringe tube,connect with cannula.It is used for small area liposuction independently,not need any other device.
Size:10ml,20ml and 50ml
3 pieces in one set(10ml 1 piece,20ml 1 piece,50ml 1 piece)
High quality glass material, can be sterilized by high temperature high pressure, can be autoclavable,unique fat collection canister for use with liposuction procedures.
Size: 1000ml
Medical grade silicone tempus implants
Two sizes:
Item 502: 52mm*42mm
Item 503: 76mm*60mm
Material: silicone
Color: white and skin tone
The silicone tempus implants are made by medical grade silicone materials-elastomer with exceptional physical and biocompatibility characteristics.
We have silicone nasal and chin implants more than 20 models and different sizes, and we can also make the order as your design.
Tumescent infiltration liposuction cannula
These cannula are used specifically for the infusion of tumescent solution. The configuration of the ports allows even distribution of the fluid.
6 pieces in one set,luer lock
One set:6 pieces
The sizes as following in one set:
Diameter x Length
1.5mm x 15cm 3 pieces
1.5mm x 20cm 2 pieces
2.0mm x 25cm 1 pieces
We also can produce the following sizes of cannulas:
Diameter: 0.8mm(21G),1.0mm(20G),1.2mm(18G),1.5mm,2mm,2.5mm,3mm,3.5mm,4mm.
Length: from 5cm to 40cm.