Please click here to check who's online and chat with them.

Gz01 Multi-Parameter Dc Voltage Transducer

Supplier From China
Apr-15-20

This is a DC voltage and current transducer. The operating principle is Photoelectric Isolation/Treble isolation. It can measure DC voltage and DC current at the same time, and has two channels of standard signal. The input, output and power supply are isolated from each other. It's featured in high accuracy, high isolation, low drift and so on. This product can be used in railway, industry control, and other fields.

Rated input: 0~1-500V; 0~0.5-5A

Output signal: 0~5V DC (Vz); 0~20mA (Iz); 4~20mA (Iy);0~10V DC (Vd);OC frequency output:(0-5KHz/0-10KHz) optional

Power supply: 12V;15V; 24V; optional

Accuracy: 0.5% optional

Output ripple: 10mV

Isolation: 2500V DC

Humidity: â?¤95%(no dew)

Load resistance: Voltage Output >2kohm; Current Outputâ?¤250ohm

Temperature drift: 500/ppm

Response time: â?¤200ms

Operating temperature:: -10~+60

Quiescent power consumptio:

Price and Minimum Quantity

Price: $45 - $55
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Gz01 Multi-Parameter Dc Voltage Transducer

GOLD Member
VERIFIED
Oct-02-20
Supplier From Singapore, Singapore, Singapore
GOLD Member
Feb-18-21
 
Product description

VFD for biomass burner, biomass gasification burner. For electric cabinet frequency and voltage converting, to meet different countries voltage. Ensure the bioamss burner can work well.
GOLD Member
May-18-19
Supplier From Pune, Maharashtra, India
Apr-15-20
Supplier From Chongqing, China
 
The one element DC multi-parameter digital transducer is used for measuring DC current, voltage and power parameters.Its inputs are DC current (output of mating transducer) and DC voltage, and its outputs are digital data of the DC current, voltage and power through RS-485 interface. It can be applied to various measuring and controlling systems such as communication, power grid and electrization railway etc.







Parameters

Part numbers: CE-AD11-34MS3-0.5/0~500V 0~5A



Description:Input: 0-500VDC,0-5ADC,Output interface: RS-485.MODBUS protocol,Power supply:24VDC(21~27V),Accuracy:0.5%,Window:none,Case style:S3



Part numbers: CE-AD11B-37MS5-0.5/0~1000V 0~5A



Description:Input: 0-1000VDC,0-5ADC,Output interface: RS-485.MODBUS protocol,Power supply:+9~55V,Accuracy:0.5%,Window:none,Case style:S5





Specifications

Voltage input: 0~25mA~500V DC (MS3)

0~25mA~1000V DC (MS5)

Current input: 0~10mA~5A DC (Output of mating Hall Effect analog current transducer)

Output data: DC Voltage, DC Current, DC Power (product of the voltage and current)

Accuracy: 0.2%

Baud rate: 1200, 2400, 4800, 9600 and 19.2K bps

Refresh period: 100 mS

Input overload: 2 times of full span (1 second, 10 times)

Power supply: +24VDC(MS3)

+9~55V(MS5)

Static power consumption: £500 mW

Operating temperature: 0~50°C

Storage temperature: -55~+85°C

Isolation voltage: >2500V DC

Application:

Digital data acquisition

Automation system integrator

Electrical distribution system

Industrial automation engineering

Process automation system
Jul-27-18
 
Function & Feature
1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input
signal.
2. These isolators can be used to prevent earth loops, which occur when a measuring source
3. Excellent temperature characteristic and good working stability.
4. It have an advantage over loop powered units, in that if for any reason the output lead should become
disconnected, the input will not be saturated.
5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
Jul-25-18
 
Function & Feature
1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input
signal.
2. These isolators can be used to prevent earth loops, which occur when a measuring source
3. Excellent temperature characteristic and good working stability.
4. It have an advantage over loop powered units, in that if for any reason the output lead should become
disconnected, the input will not be saturated.
5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
Specifications
Inputs:
System input 0~5V, 0~30V, 0~60V, 0~300V, 0~400V
Absorbed power 0.1VA
Output:
Standard nominal outputs 4~20mA, 0-5V,
(others on request) 0-20mA,
5-10V
0-10V
Respones time
Jul-27-18
 
Function & Feature
1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input
signal.
2. These isolators can be used to prevent earth loops, which occur when a measuring source
3. Excellent temperature characteristic and good working stability.
4. It have an advantage over loop powered units, in that if for any reason the output lead should become
disconnected, the input will not be saturated.
5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
6. Ultra-thin dimension, suitable for limited space, the control cabinet.
Jul-25-18
 
Function & Feature
1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input
signal.
2. These isolators can be used to prevent earth loops, which occur when a measuring source
3. Excellent temperature characteristic and good working stability.
4. It have an advantage over loop powered units, in that if for any reason the output lead should become
disconnected, the input will not be saturated.
5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
6. Ultra-thin dimension, suitable for limited space, the control cabinet.
Specifications
Inputs:
System input 0~5V, 0~30V, 0~60V, 0~300V, 0~400V
Absorbed power 0.1VA
Output:
Standard nominal outputs 4~20mA, 0-5V,
(others on request) 0-20mA,
5-10V
0-10V
Respones time
GOLD Member