(Pressure Monitoring Line)
DEHP free PVC tube; ID ¸ 1.2+ 0.1mm; OD ¸ 2.8 + 0.1mm
6% taper in luer lock allows connection with a variety of medical devices
Female connector ABS material
Luer lock ABS material
Individual Packaging in Peel Open Pouch
E.O. Sterile
Pressure Monitoring lines are used to transmit the invasive blood pressure (via IV Cannula) to the Pressure Monitoring System. It also can be used with syringe infusion pump.
High pressure monitoring line is used for high pressure monitoring, and connection between syringe infusion pump and patient. Provided with universal male luer lock and female luer lock at either end to ensure securely fit all standard equipment.
SPECIFICATION
Made of clear and non-toxic PVC / DEHP Free PVC
Highly kink resistant tubing
Latex Free, non-pyrogenic
Connectors: Male - female, Male - Male
Diameter: OD 2.4 mm, ID 1.1 mm
Tube Lengths: 10, 25, 50, 100, 150, 200 cm
Single-use, EO Sterilized & Individually Packed
-Manufactured from non-toxic medical grade P.V.C. material and able to withstand a pressure of 580 PSI.
-Fitted with male/female&male/male luer locks for secure connection.
-Does not bulge even at high pressure.
-Minimal dead space.
-E.T.O. Sterile and Pyrogen Free. Also available in P.E. Material.
-Size : 10/25/50/100/150/200 cm
-Colour : Red/Blue/Yellow/Clear (Other colours and sizes also available on demand)
-Braided tubing
-Used for power injection applicator
-Combines high pressure capacity with superior flexibility
-Available with or without high pressure rotating adapter
-Latex free
-The following High pressure line are available in Male Male Lure Lock.
-Size : 25, 50, 100, 120, 150, 200CM Male Female LL
An intelligent device system with ( REM) Return electrode monitoring systems which kept continuous monitoring of patient impedance level and deactivate the generator if the fault in the patient/ return electrode contact is detected minimize the chances of burning .
Memory record feature , with Real time Monitoring and instance response system for tissue density it samples the current and voltage 450,000 times per second which enables it to respond tissue impedance change in less then 10 millisecond which insuring the machine achieves optimum energy output levels quicker and more accurately- ensuring that only the precise voltage needed is safely delivered to each tissue type .
1. two pencil can work simultaneously. ( Optional )
2.Automatic start and stop . ( Optional )
3, wireless foot switch operational ( Optional)
4.Copatibale with other equipment ( Argan Plasma Coagulation system, Optimum smoke evacuation system )
Application of uses : General surgery, Gastroenterology, Dermatology, vascular surgery ,Obstetrics & Genecology, Heart/ Thoracic surgery , ORL/ENT, , Minimal Invasive surgery, cerebral surgery Neurosurgery ,Orthopedic & Plastic Surgery, Trans Urethral Resection ( Tur) etc