Please click here to check who's online and chat with them.

German Railway Track Equipment (zhejiang) Co., Ltd

Supplier From China
Sep-30-21

Product Features

JWXC-1700 type infinite relay (hereinafter referred to as relay) is used as a general relay in the signal circuit.



Features

1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized.

2. It adopts silver-silver oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance.

3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the ferromagnetic parts of the magnetic circuit from magnetization, and ensure the reliable fall of the relay.

4. The contact system is composed of ordinary contacts, with eight groups of common contacts for switching on and off.

5. The rated voltage of the relay is DC 24V.



Applicable environment

The applicable environment of the relay is:

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25â??);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: vibration is not more than 15Hz, amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Mechanical properties

Number of contact groups: 8QH;

Identification pin number: 11, 51;

Contact gap: not less than 1.3mm;

Pallet gap: not less than 0.35mm;

Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN;

Contact uniformity error: not more than 0.20mm.



Electrical characteristics (at 20c)

Coil resistance: 850 (1±10%) 2

The coils are connected in series, connect 2, 3, use 1, 4;

Rated value: DC24V;

Magnetizing value: DC67V;

Working value: not more than DC16.8V;

Release value: not less than DC3.4V;

Reverse working value: not more than DC18.4V;

Contact resistance: not more than 0.05.



Insulation withstand voltage

Under the standard atmospheric conditions of the test, the absolute resistance of the relay should not be less than 100MQ.

Under the condition that the air pressure is not less than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz,

2000V rms voltage, there should be no breakdown flashover after 1 min, and the voltage during repeated test should be 75% of the original test voltage.



Product electrical life

The relay contacts are connected to DC24V1A resistive load; its electrical life is 2106 times.


product name

There are extremely strengthened contact relays: JYJXC-160/260



Product Usage

The JYJXC-160/260 type has pole reinforced contact relay is used as a two-start relay in the signal switch control circuit.



Mechanical properties

Number of contact groups: 2DF, 2DFJ;

Identification pin number: 15, 54;

Contact gap: ordinary contact is not less than 4.5mm; reinforced contact is not less than 7mm;

Pallet gap: ordinary contact point is not less than 0.35mm;

Ordinary contact pressure: the positioning contact is not less than 150mN; the reverse contact is not less than 150mN;

Strengthen the contact pressure: the positioning contact is not less than 400mN; the reverse contact is not less than 400mN;

Contact uniformity error: no more than 0.2mm between ordinary contacts and ordinary contacts and between ordinary contacts and reinforced contacts, and no greater than between reinforced contacts and reinforced contacts 0.1mm.

Positioning or reverse position holding force is not less than 4N;



Electrical characteristics (at 20c)

Coil resistance: 135/220Q

Use the coil alone, use 1, 23, 4;

Rated value: 24V;

Magnetizing value: 64V/64V;

Rotation extreme value: forward 10V~16V, reverse 10V~16V;

Contact resistance: common contact is not more than 0.05; strengthened contact is not more than 0.1Q.



Product function

The signal relay is an important component in the interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services.



Insulation withstand voltage

Under the standard atmospheric conditions of the test, the insulation resistance of the relay should not be less than 100MQ.

Under the condition that the air pressure is not less than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz,

2000V rms voltage, there should be no breakdown flashover after 1 min, and the voltage during repeated test should be 75% of the original test voltage.



Product electrical life

The ordinary contact of the relay is connected to DC24V1A resistive load; the strengthened contact is connected to DC220V7.5A, 0.05H inductive load, and its electrical life is 1105 times.


Product Usage

The JZXC-H18 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit.



Installation Precautions

1. When installing the relay, make sure that the insulation interval between the sockets is intact, the socket hanging spring is intact, and the socket identification pin is in the correct position and should not be missing.

2. Pay attention to the relative position between the relay and the socket when plugging in the relay to avoid damage to the relay or socket during plugging.

3. When repairing and replacing the relay, first remove the fixed relay spring, and then pull out the relay. Do not use excessive force or shake left and right when pulling it out, as it may damage the relay or socket.



Applicable environment

a) Ambient temperature: -40~+60

b) Relative humidity: not more than 90% (temperature +25);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Product electrical life

The relay contact is connected to DC24V1A resistive load; its electrical life is 1Ã??106 times



Structural characteristics

The electromagnetic system includes coils, iron cores, irons and armatures. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil.

It is mainly to install a half-wave or full-wave rectifier circuit composed of diodes above the contact group.


Product Introduction

The JZXC-480 rectifier relay is an important component in the chain equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays.



Product Usage

The JZXC-480 rectifier relay is used as an AC rail and AC accident relay in the signal circuit.



test method

Requirements for testing measuring tools, meters, and power supply

(1) The accuracy of the measuring tool for measuring the shape and installation dimensions should not be less than 0.05mm; the accuracy of the feeler gauge should not be less than level 2; the measurement error of the force measurement should not be greater than 2%.

(2) The accuracy of the DC voltmeter and ammeter used for testing should not be less than 0.5, and the accuracy of the AC (50Hz) voltmeter and ammeter should not be less than 1

(3) The power supply voltage should remain stable, and its fluctuation range should not exceed 5%. The DC power supply should be a DC generator, battery or AC full-wave rectifier power supply (except for special regulations, the ripple factor should not be greater than 5%). The waveform of the AC power supply should be a sine wave with a frequency of 50 Hz.



Features

The relay is composed of a DC infinite relay and a full-wave rectifier circuit.



Applicable environment

a) Ambient temperature: -40â??~+60â??;

b) Relative humidity: not more than 90% (temperature +25â??);

c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Dimensions

165mm 49mm 163mm (length width height)



Installation method

The relay socket is installed on the combination frame (cabinet) with bolts, and the relay is inserted into the socket horizontally and clamped with a hanging spring.

Relay identification pin numbers 13, 54.



Mechanical properties

Number of contact groups: 4QH; 2Q

Identification pin number: 13, 55;

Contact gap: not less than 1.3mm;

Pallet gap: not less than 0.35mm;

Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN;

Contact uniformity error: not more than 0.20mm.


Product Introduction

JWJXC-H125/0.44 stepless enhanced contact slow release relay is an important component in interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and Close and so on. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays.

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

JW.JXC-H125/0.44. The stepless strengthened contact slow release relay is used as a general relay in the signal circuit.



Applicable environment

a) Ambient temperature: -40~+60

b) Relative humidity: not more than 90% (temperature +25);

C) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Structural characteristics

Mechanical properties

Number of contact groups: 2QH, 2QJ, 2H;

Identification pin number: 15, 55;

Ordinary contact gap: not less than 1.3mm;

Strengthen the contact gap: not less than 2.5mm;

Ordinary pallet gap: not less than 0.35mm;

Reinforce the gap of the support plate: not less than 0.1-0.3mm;

Ordinary contact pressure: dynamic closing or positioning contact not less than 150mN; dynamic breaking or reverse position contact not less than 150mN;

Strengthen the contact pressure: the dynamic closing or positioning contact is not less than 400mN; the dynamic breaking or reverse position contact is not less than 300mN;

Contact uniformity error: not more than 0.20mm.


Nov-11-21

roduct Usage

The transmission relay is one of the important equipment in the AC counting code automatic blocking equipment. The DC pulse sent by the electric code transmitter is transformed into an AC pulse by the transmission relay, and then sent to the track circuit.

JCZC1-72 transmission relay is used for automatic blocking interval.



Features

Heavy spring force relay.



Dimensions

165mm 49mm 163mm (length width height)

Installation method

The relay socket is installed on the combination pear (cabinet) with bolts, and the relay is horizontally inserted into the socket and clamped with a hanging spring.

Relay identification pin numbers 13, 53.

Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.
maintenance

Daily maintenance and maintenance items are as follows:

a) Keep the relay and socket clean;

b) Observe whether the relay operation status is normal;

c) The relay should be replaced in time for abnormal operating conditions and serious contact burnout.
Regular maintenance:

In the electrical life and life management cycle of the relay, the maintenance cycle of the stepless relay and the rectifier relay should be five years;

The overhaul period of stepless enhanced contact relays, poled relays and biased pole relays should be three years;

The overhaul period of stepped reinforced contact relays should be one year.

Appearance inspection and performance


Product Features

JSDPC-1000 dynamic relay, JSDPC-820 dynamic relay, and JSDPC-830 dynamic relay were once used in microcomputer interlock interface circuit.

At present, JSDPC-1000 dynamic relays, JSDPC-820 dynamic relays, and JSDPC-830 dynamic relays have ceased to be used on large railways, and are only used in hump circuits when users require them.



Features

1. Two-way dynamic control signal relay.

2. Controlled by dynamic pulse signal.

3. Dynamic pulse control signal:

JSDPC-1000 dynamic relay is 24V, 2.5Hz.

JSDPC-820 dynamic relay is 24V, 1Hz.

JSDPC-830 dynamic relay is 24V, 5Hz.


3. When repairing or replacing the relay, first remove the national relay spring, and then pull out the relay. Do not use excessive force or shake left and right when pulling it out, as it may damage the relay or socket.



Faults and troubleshooting methods

1. The relay contact has no output

The analysis and elimination methods of the relay contact without output are as follows:

(1) Make sure that the relay and socket should be reliably plugged in;

(2) Check that the relay should not be mechanically blocked. If foreign matter in the relay blocks the armature, the armature cannot work reliably (forward rotation) or release (reverse rotation), and the contacts cannot be reliably contacted;

(3) Check that there should be no foreign matter between the contacts, there is foreign matter between the contacts, and the contacts cannot be reliably contacted;

(4) Check that the contact resistance of the relay contact should not be too large.

2. The relay does not work or the relay with a pole cannot be reversed in the forward direction
be reliably released.


Product Introduction

JWXC-1000 type infinite relay is used to close and open the special multi-way switch of signal control circuit. It is an important part of railway signal. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the action of the relay directly affects the reliability and safety of the signal system.



Features

JWXC-1000 type infinite relay is one of the main components in railway signal equipment. Its reliability and safety in use are necessary requirements to ensure the normal operation of various automatic control and remote control signal equipment.



Product function

The signal relay is an important component in the interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the whole line are the keys to the safety of railway transportation and operation services.



Product Usage

The JWXC-1000 type infinite relay is used as a general relay in the signal circuit.



Executive standard

GB/T7417-2010 "Railway Signal AX Series Relay"



Product Usage

JWXC-1000 type infinite relay (hereinafter referred to as relay) is used as a general relay in the signal circuit.



Applicable environment

The applicable environment of the relay is:

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Applicable characteristics

Mechanical properties

Number of contact groups: 8QH;

Identification pin number: 11, 52;

Contact gap: not less than 1.3mm;

Pallet gap: not less than 0.35mm;

Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN;

Contact uniformity error: not more than 0.20mm.



Electrical characteristics


Product Usage

The JZXC-H18 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit.


The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the armature by the butterfly-shaped steel wire, and it moves flexibly. There is a heavy hammer in the transmission part of the armature to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, vehicle iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence.



Product characteristics Mechanical characteristics

Number of contact groups: 4QH;

Identification pin number: 13, 53;

Contact gap: not less than 1.3mm;

Pallet gap: not less than 0.35mm;

Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN;

Contact uniformity error: not more than 0.20mm.



Electrical characteristics


Product Usage

The JWXC-2.3 type infinite relay is used as a DC track relay in the signal circuit.



Features

1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized.

2. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance.

3. The magnetic circuit adopts electromagnetic pure iron material with small residual, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay.

4. The contact system is composed of ordinary contacts, and there are four groups of ordinary contacts for switching on and off.

5.The rated current of the relay is 280mA DC.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25);

c) Air pressure: not less than 70KPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



product structure

Infinite relay is the typical structure of Ax series relay, which is composed of electromagnetic system and contact system. The electromagnetic system includes coil, iron core, choke and armature. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the iron by a butterfly-shaped steel wire, which is flexible in movement. There is a heavy hammer in the transmission part of the armature to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, choke iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence.



Installation method


JZXC-0.14 type rectifier relay is an important element in interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the way, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays.

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

The JZXC-0.14 type rectifier relay is used in the signal circuit for the filament supervision or conversion relay for the electric concentration of small stations and the local power supply in the automatic block section.



Features

1. The relay is a heavy elastic rectifier electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized.

2. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance.

3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay.

4. The relay is composed of a half-wave rectifier circuit and an infinite relay. The input of the rectifier is alternating current, and the output of the rectifier is ~ Darudapin current 1, current.

5. The relay contact system consists of common contacts, with four groups of common contacts for switching on and off.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Dimensions

Relay: 165mm 49mm 163mm (length width height)

Socket: 157mm 48mm 22mm (length width height)


Executive standard

GB/T7417-2010 "Railway Signal AX Series Relay"



product structure

The electromagnetic system of the stepless enhanced contact slow release relay is the same as that of the stepless slow release relay (JWXC-H340). The magnetic circuit system of the JWJXC-H125/80 stepless enhanced contact slow release relay adds a copper short-circuit ring to make the slow release time longer.

The contact system consists of two parts: ordinary contacts and enhanced contacts. The structure of ordinary contacts is the same as that of non-polar relays, and the reinforced contacts are specially designed high-power contacts and arc wave devices.



Product Usage

The transmission relay is one of the important equipment in the AC counting code automatic blocking equipment. The DC pulse sent by the electric code transmitter is transformed into an AC pulse by the relay, and then sent to the track circuit.

JCZC2-2000 transmission relay is used in the station.



Features

Heavy spring force relay.

It is necessary to install a shock absorber when in use.



Mechanical properties

Number of contact groups: 2QHJ; 2QH

Identification pin number: 14, 53;

Strengthen the contact gap: not less than 1.5mm;

Ordinary contact gap: not less than 0.8mm;

Strengthen the contact pressure: the front contact is not less than 450mN; the rear contact is not less than 450mN;

Ordinary contact pressure: the front contact is not less than 250mN; the rear contact is not less than 250mN;

The air gap between the iron core and the street iron when the relay is working: not more than 0.20mm.

Strengthen the contact pressure on the transmission rod: not less than 100mN.

Strengthen the joint travel: not less than 0.1mm.

Common travel of common contacts: not less than 0.25mm.

Radial travel distance of street iron: 0.3mm-0.7mm.

Street rail vertical travel: 0.3mm-0.5mm.

Street rail axial travel: 0.05mm-0.15mm.


Product Usage

The JC type AC relay is used as a buck-boost control relay, a signal switch track power supply supervisory relay, and a main screen and a backup screen conversion relay in the power supply screen. Can replace JZXC-20000 rectifier relay.



Features

1. The relay is an AC 220V heavy spring force electromagnetic relay with reinforced contacts.

2. The relay magnetic system is a clap-on AC magnetic system, which is composed of an iron core, a coil and an armature.

3. It adopts silver-silver oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance.

4. The contact system is composed of ordinary contacts. There are four groups of moving on and off conversion ordinary contacts and two groups of moving and closing ordinary contacts. The structure of the ordinary contacts is the same as that of a non-polar relay.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Dimensions


Product Introduction

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

The JJC1 AC enhanced contact relay is a reversible motor control relay in the power supply screen. It can replace JZJXC-7200 rectifier strengthened contact relay.



Features

1. The JJC type AC enhanced contact relay is an AC 24V heavy elastic type enhanced contact electromagnetic relay.

2. The relay magnetic system is a clap-on AC magnetic system, which is composed of an iron core, a coil and an armature.

3. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance.

4. The relay contact system is composed of two parts: ordinary contacts and enhanced contacts. There are two groups of movable and broken ordinary contacts; four groups of movable and closed enhanced contacts. The structure of ordinary contacts is the same as that of non-polar relays. The enhanced contacts are specially designed high-power contacts.



Mechanical properties

Number of contact groups: 4QJ; 2H

Identification pin number: 12, 54;

Ordinary contact gap: not less than 1.3mm;

Strengthen the contact gap: not less than 5mm;

Ordinary pallet gap: not less than 0.35mm;

Reinforce the gap of the support plate: not less than 0.1-0.3mm;

Ordinary contact pressure: dynamic breaking contact is not less than 150mN;

Strengthen the contact pressure: the moving and closing contact is not less than 600mN;

Contact uniformity error: not more than 0.20mm.


Product Introduction

The JJJC5 AC enhanced contact relay is an important element in the interlocking equipment, and the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the way, and control the opening and closing of the signal machine. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

The JJ small C5 AC enhanced contact relay is used as an indicator light power supply supervisory relay in the power supply screen of the small station.



Mechanical properties

Number of contact groups: 2QHJ; 2QH

Identification pin number: 13, 43;

Ordinary contact gap: not less than 1.3mm;

Strengthen the contact gap: not less than 4mm;

Ordinary pallet gap: not less than 0.35mm;

Reinforce the gap of the support plate: not less than 0.1-0.3mm;

Ordinary contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN;

Strengthen the contact pressure: the dynamic contact point is not less than 600mN; the dynamic disconnection point is not less than 300mN;

Contact uniformity error: not more than 0.20mm.


Applicable environment

a) Ambient temperature: -5~+40;

b) Relatively moderate: not more than 90% (temperature +25);

c) Air pressure: not less than 70KPa (equivalent to an altitude below 3000m);

d) Vibration: the frame frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Rated voltage: DC 24V, voltage fluctuation range 24X (1±10%V;

f) Working position: horizontal;

g) There is no harmful gas causing explosion hazard around, and good dust-proof measures should be applied.



Mechanical properties

1614998643577125.jpg



Precautions

a) The identification pin numbers of the programmable time relays are the same. Please confirm the corresponding slow suction time of the corresponding type of relay before use.

b) Terminals 1, 2, 3, and 4 of the two coils of the relay are directly connected in parallel with the two diodes on the printed circuit; therefore, when measuring the electrical characteristics of the relay, the positive pole of the power supply must be connected to the terminals 1, 3, and the negative pole of the power supply must be connected to the terminals 1, 3. On terminals 2, 4.

C) Contacts 11 and 12 are already occupied by the relay, and the number of contacts that can be used by the user is 2QH, 1Q.

d) The position of the relay contact system is shown in Figure 1. When in use, the socket must be equipped with an identification pin.

e) The use environment of the relay should have good ventilation conditions and dust-proof equipment. And used in specially designed circuits; in special circumstances, the electrical characteristics and contact capacity of the relay should be considered to ensure the reliable operation of the relay.


Product Introduction

The JJJC7 AC enhanced contact relay is an important element in the interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and the opening and closing of the signal machine. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

The JJC7 AC enhanced contact relay is used in the distributed power supply screen.



Features

1. The JJJC7 type relay is an AC 220V heavy spring force type reinforced contact electromagnetic relay.

2. The relay magnetic system is a clap-on AC magnetic system, which is composed of an iron core, a coil and an armature.

3. The use of silver-silver oxidation requires contacts, which has the characteristics of strong anti-adhesion and low contact resistance.

4. The relay contact system consists of two parts: ordinary contacts and enhanced contacts. There are two groups of moving on and off switching ordinary contacts; the two sets of moving on and off switching enhanced contacts, the structure of the ordinary contacts is the same as the stepless relay, and the strengthened contacts Specially designed high-power contacts.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Insulation withstand voltage

Under the standard atmospheric conditions of the test, the absolute resistance of the relay should not be less than 100MQ.

Under the condition that the air pressure is not lower than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz, 2000V rms voltage, there should be no breakdown flashover after 1min, the voltage when repeating the test Should be 75% of the original test voltage value.


Product Usage

Programmable time relays include JSBXC-780, JSBXC-820, JSBXC-820, JSBXC1-850, and JSBXC1-870 series relays. Each type of relay has four types of warm-up time to choose from, among which JSBXC1-870 series The heating time can also be changed according to the special requirements of users.

The relay is used as a delay control in the circuit.



Applicable environment

a) Ambient temperature: -5~+40;

b) Relatively moderate: not more than 90% (temperature +25);

c) Air pressure: not less than 70KPa (equivalent to an altitude below 3000m);

d) Vibration: the frame rate is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Rated voltage: DC 24V, voltage fluctuation range 24X (1�±10%) V;

f) Working position: horizontal;

g) There is no harmful gas causing explosion hazard around, and good dust-proof measures should be applied.



Mechanical properties

1614996944256898.jpg



Electrical characteristics

.jpg

Note: The error range of the resistance value of the relay coil is ±(nominal resistance value10%)



Time characteristics


product name

AC filament conversion relay: JZSJC2 product usage

JZSJC2 AC Filament Conversion Relay is suitable for railway signal lighting circuit. When the main filament of the 12V, 25w dual-filament signal bulb is broken, the auxiliary filament will be lit through a set of movable break contacts to realize the conversion of the main and auxiliary filaments. , And alarm through another set of contacts.



Applicable environment

a) Temperature: -40~+60;

b) Air pressure: not less than 70kPa (equivalent to 3000m above sea level);

c) Relative humidity: not more than 90% (temperature -25C);

d) Vibration: frequency 5H2~2H2, displacement amplitude not greater than 1mm, frequency 22H2-50H2, acceleration amplitude not greater than 20m/s2;

e) There should be no harmful gas causing explosion hazard around, and dust-proof measures should be taken.



Mechanical properties

Contact gap: not less than 0.8mm;

Dynamic contact pressure: not less than 150mN;

Dynamic breaking contact pressure: not less than 150mN;

Contact uniformity error: not more than 0.1mm;

The joints are formed together: not less than 0.1mm.



Electrical characteristics

Rated current: 2.1AAC;

Working value: not more than 1.5AAC;

Release value: not less than 0.5AAC;

Contact resistance: no more than 0.052



Insulation resistance

The temperature of the relay and socket is 15C~35, the relative humidity is 45%~80%, and the insulation resistance should not be less than 100M.


product name

AC filament conversion relay: JZSJC2 product usage

JZSJC2 AC Filament Conversion Relay is suitable for railway signal lighting circuit. When the main filament of the 12V, 25w dual-filament signal bulb is broken, the auxiliary filament will be lit through a set of movable break contacts to realize the conversion of the main and auxiliary filaments. , And alarm through another set of contacts.



Applicable environment

a) Temperature: -40~+60;

b) Air pressure: not less than 70kPa (equivalent to 3000m above sea level);

c) Relative humidity: not more than 90% (temperature -25C);

d) Vibration: frequency 5H2~2H2, displacement amplitude not greater than 1mm, frequency 22H2-50H2, acceleration amplitude not greater than 20m/s2;

e) There should be no harmful gas causing explosion hazard around, and dust-proof measures should be taken.



Mechanical properties

Contact gap: not less than 0.8mm;

Dynamic contact pressure: not less than 150mN;

Dynamic breaking contact pressure: not less than 150mN;

Contact uniformity error: not more than 0.1mm;

The joints are formed together: not less than 0.1mm.



Electrical characteristics

Rated current: 2.1AAC;

Working value: not more than 1.5AAC;

Release value: not less than 0.5AAC;

Contact resistance: no more than 0.052



Insulation resistance

The temperature of the relay and socket is 15C~35â??, the relative humidity is 45%~80%, and the insulation resistance should not be less than 100M�©.



Insulation withstand voltage

Between the coil winding and other parts of the relay, the insulation withstand voltage between each contact and the contact and the ground should be able to withstand AC sine wave 50Hz, 1000V effective value voltage for 1Min, there should be no breakdown or flashover.



Product electrical life

Wei Electric implements broken wire conversion according to the lighting circuit, 15 to 20 actions per minute, and its electrical life is not less than 3*105



test method

Requirements for test satellites, meters, and power supplies

The accuracy of the measuring gauge should not be less than 0.02mm;

The accuracy of the feeler gauge should not be lower than level 2;

The measurement error of the dynamometer should not be greater than 2%;

The accuracy of the AC ammeter used for testing should not be lower than level 1;

The power supply voltage fluctuation range should not exceed 5%, the waveform is a sine wave, and the frequency is 50�±1Hz.



Characteristic test

The electrical characteristics test circuit of the relay is shown in the figure below.


Product Usage

The JZXC-H156 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Mechanical properties

Number of contact groups: 4QH;

Identification pin number: 22, 53;

Contact gap: not less than 1.3mm;

Pallet gap: not less than 0.35mm;

Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN;

Contact uniformity error: not more than 0.20mm.



Electrical characteristics

Rating: AC51MA

Magnetizing value: AC136Ma

Release value: not less than AC12Ma

Working value: not less than AC34ma

Coil resistance: 78 (1±10%) Q2

The coils are connected in series, connect 1, 4, use 5, 6;


Product Usage

The JZXC-H156 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Mechanical properties

Number of contact groups: 4QH;

Identification pin number: 22, 53;

Contact gap: not less than 1.3mm;

Pallet gap: not less than 0.35mm;

Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN;

Contact uniformity error: not more than 0.20mm.



Electrical characteristics

Rating: AC51MA

Magnetizing value: AC136Ma

Release value: not less than AC12Ma

Working value: not less than AC34ma

Coil resistance: 78 (1±10%) Q2

The coils are connected in series, connect 1, 4, use 5, 6;


product description

The JZXC-H60 rectifier slow release relay is an important component in the interlocking equipment, and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and closing of the signal machine, etc. . Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays.



Product Usage

The JZXC-H60 rectifier slow release relay is used in the signal circuit for the LED signal lighting circuit.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Mechanical properties

Number of contact groups: 4QH;

Identification pin number: 13, 53;

Contact gap: not less than 1.3mm;

Pallet gap: not less than 0.35mm;

Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN;

Contact uniformity error: not more than 0.20mm.



Electrical characteristics

Magnetizing value: AC240Ma

Release value: not less than AC30Ma

Working value: not less than AC60ma

Coil resistance: 30 (1±10%) Q2

The coils are connected in series, connect 1, 4, use 5, 6;


Product Introduction

JZXC-H142 type rectifier slow release relay is an important component in interlocking equipment. It is the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and closing of the signal machine, etc. . Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays.

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product function

JZXC-H142 rectifier slow release relay is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits.



Product Usage

The JZXC-H142 rectifier slow release relay is used in the signal circuit for the LED signal lighting circuit.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.


Product Introduction

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.

The JZXC-H62 rectifier slow release relay is an important component in the chain equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and closing of the signal machine, etc. . Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays.



Product Usage

JZXC-H62 type rectifier slow release relay is used in signal circuit for turnout display circuit and single-multi-line semi-automatic blocking circuit.



Features

JZXC-H62 rectifier slow release relay is one of the main components in railway signal equipment. Its reliability and safety in use are necessary requirements to ensure the normal operation of various automatic control and remote control signal equipment.



Product function

The signal relay is an important component in the interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25);

C) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Executive standard

Q/SX0410.06-2012 "AX Series Relay"

Product Features

Mechanical properties

Number of contact groups: 4QH;

Identification pin number: 13, 53;

Contact gap: not less than 1.3mm;

Pallet gap: not less than 0.35mm;

Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN;

Contact uniformity error: not more than 0.20mm.


Product Usage

The JZJXC-7200 rectifier enhanced contact relay is used as a reversible motor control relay in the power supply screen.



Features

1. The JZJXC-7200 and JZJXC-100 relays are AC 220V, AC 24V heavy-elasticity reinforced contact rectifier electromagnetic relays, adopting the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized.

2. It adopts silver-silver oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance.

3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay.

4. The magnetic circuit system of the relay is basically the same as the JWJXC-7200 stepless enhanced contact relay.

5. The contact system is composed of two parts: ordinary contacts and reinforced contacts. There are two groups of moving and breaking ordinary contacts; four groups of moving and closing reinforced contacts without arc extinguishing magnets. The structure of ordinary contacts is the same as that of non-polar relays. The reinforced contacts are specially designed. Of high-power contacts.

6. The relay has a rectifier unit attached to it because there is no place to install the rectifier unit on the contact group. The rectifier unit is a full-wave rectifier composed of four 1N4007 silicon rectifier diodes.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.


Product Features

The JZXC-20000 rectifier relay is used as a buck-boost control relay in the power supply screen; as a signal channel and track power supervision relay; and a conversion relay between the main screen and the backup screen.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Features

1. The relay is an AC 220V heavy elastic rectifier electromagnetic relay, which adopts the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized.

2. It adopts silver-silver oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance.

3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay.

4. The relay consists of two parts: a rectifier circuit and a non-polar relay. The rectifier circuit is a bridge rectifier circuit composed of four 1N4007 silicon rectifier diodes. The input of the rectifier is alternating current, and the rectified current output to the coil is direct current.

5. The relay contact system is composed of common contacts, with six groups of common contacts for switching on and off.



Mechanical properties

Number of contact groups: 6QH;

Identification pin number: 23, 55;

Contact gap: not less than 1.3mm;

Pallet gap: not less than 0.35mm;

Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN;

Contact uniformity error: not more than 0.20mm.



Electrical characteristics

Rated value: AC220V Magnetizing value: AC220V Release value: not less than AC 35V Working value: not more than AC105V Coil resistance: 10000 (1±10%) Q2 coils in series, connect 1, 4, use 7, 8; time characteristics (At rated voltage): The pull-in time is not more than 01S, and the slow release time is not more than 0.15


Product Features

The JZXC-H18F1 (formerly JJXC-H15) type rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit.



Applicable environment

a) Ambient temperature: 40~+60;

b) Relative humidity: not more than 90% (temperature +25);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Features

1. The relay is a heavy spring force DC electromagnetic relay, which uses the principle of constant gravity to force the moving and closing contacts to open when the coil is de-energized.

2. It adopts silver-silver oxidized vehicle contact, which has the characteristics of strong anti-adhesion and low contact resistance.

3. The magnetic circuit adopts electromagnetic pure iron material with small residual current, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the ferromagnetic parts of the magnetic circuit from magnetization, and ensure the reliable fall of the relay.

4. The relay is a new product improved on the basis of the JJXC-15 filament relay. The relay has no rectifier unit, and the AC power supply is directly connected to the coil, which has a certain anti-lightning function. The wiring terminal of the relay is exactly the same as the JUXC-15 filament relay, so it is completely interchangeable, and there is no need to change the wiring on site.

5. The relay contact system consists of common contacts, with four groups of common contacts for switching on and off.

6. The relay should be used in conjunction with the isolation transformer to adjust the system current to ensure reliable operation and release of the relay, and to ensure that the lamp terminal voltage meets the specified adjustment range.


Product Introduction

JZXC-H0.14/0.14 rectifier slow release relay is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays.



Product Features

The JZXC-H0.14/0.14 rectifier slow release relay is used as a filament conversion relay in the signal lighting circuit of a crossing.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25);

c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Features


Product Introduction

The JZXC-H18F rectifier slow release relay is an important component in the interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays.



Product Usage

The JZXC-H18F rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit.



Features

1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized.

2. The use of silver-silver oxidation requires contacts, which has the characteristics of strong anti-adhesion and low contact resistance.

3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the ferromagnetic parts of the magnetic circuit from magnetization, and ensure the reliable fall of the relay.

4. The relay is a new product improved on the basis of the JZXC-H18 rectifier relay. The relay has no rectifier unit, and the AC power supply is directly connected to the coil, which has a certain anti-lightning function. The wiring terminal of the relay is exactly the same as the JZXC-H18 rectifier relay, so it is interchangeable, and there is no need to change the wiring on site.

5. The relay contact system consists of common contacts, with four groups of common contacts for switching on and off.

6. The relay should be used in conjunction with the isolation transformer to adjust the system current to ensure the reliable operation and release of the relay, and to ensure that the lamp terminal voltage meets the specified adjustment range.


Product Introduction

JZXC-16/16 is a dedicated multiplexer used to close and open the signal control circuit. It is an important part of railway signals. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system.



Product Features

The JZXC-16/16 (formerly known as JZXC-16F) rectifier relay has a high return coefficient, which is used to automatically block the signal lighting circuit of the interval and solve the problem of large leakage current in long-distance power supply cables and unreliable release of the filament supervision relay.



Features

1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized.

2. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance.

3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay.

4. The front ring of the relay is a diode-enclosed short-circuit coil, without a rectifier unit, and the AC power supply is directly connected to the coil, which has a certain anti-lightning function.

5. The relay contact system consists of common contacts, with four groups of common contacts for switching on and off.

6. The relay should be used in conjunction with the isolation transformer to adjust the system current to ensure the reliable operation and release of the relay, and to ensure that the lamp terminal voltage meets the sp


Product Introduction

JPXC-1000 biased pole relay is an important component in interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the way, and control the opening and closing of the signal machine.

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

The JPXC-1000 biased pole relay is designed to identify the polarity of the current in the signal circuit. In the signal circuit, it is used in the turnout indication circuit and the single-multiplex semi-automatic blocking circuit.



Features

1. The relay adds a pole-biased magnet to the magnetic circuit, so that the armature is biased to the drop position by the permanent magnetic force. The pull-up of the armature is related to the polarity of the current in the coil. When the current through the coil is in the specified direction, the armature is pulled up, and when the direction of the current is opposite, the armature remains stationary. It only has a stable state, that is, after the armature is sucked up by electromagnetic force, it will fall when the power is cut off, and it will always be in a falling positioning state.

2. The relay is a heavy spring force DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is powered off.

3. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance.

4. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay.

5. The relay contact system is composed of ordinary contacts, with 8 groups of ordinary moving on and moving off conversion contacts.

6. The rated voltage of the relay is DC 24V.


Product Usage

The JZJXC-100 type rectifier strengthened contact relay is used as a power supply supervisory relay for the indicator light in the power supply screen.



Applicable environment

a) Ambient temperature: -40~+60

b) Relative humidity: not more than 90% (temperature +25C);

C) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Mechanical properties

Number of contact groups: 4QJ; 2H

Identification pin number: 22, 32;

Ordinary contact gap: not less than 1.3mm;

Strengthen the contact gap: not less than 7mm;

Ordinary pallet gap: not less than 0.35mm;

Reinforce the gap of the support plate: not less than 0.1-0.3mm;

Ordinary contact pressure: dynamic breaking contact is not less than 200mN;

Strengthen the contact pressure: the moving and closing contact is not less than 600mN;

Contact uniformity error: not more than 0.20mm.



Electrical characteristics

Rating: AC24V

Magnetizing value: AC24V

Release value: not less than AC4V

Working value: not more than AC11V

Coil resistance: 50 (1±10%) Q2

Coils are connected in series, connect 2, 3, use 1, 4


product description

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

JZXC-480F lightning protection rectifier relay is used as AC track and AC accident relay in signal circuit.



Product function

It is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits.



Applicable environment

a) Ambient temperature: -40â??~+60â??;

b) Relative humidity: not more than 90% (temperature +25�°C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Mechanical properties

Number of contact groups: 4QH; 2Q

Identification pin number: 13, 55;

Contact gap: not less than 1.3mm;

Pallet gap: not less than 0.35mm;

Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN;

Contact uniformity error: not more than 0.20mm.


Product Usage

The JZXC-H18 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit.



Installation Precautions

1. When installing the relay, make sure that the insulation interval between the sockets is intact, the socket hanging spring is intact, and the socket identification pin is in the correct position and should not be missing.

2. Pay attention to the relative position between the relay and the socket when plugging in the relay to avoid damage to the relay or socket during plugging.

3. When repairing and replacing the relay, first remove the fixed relay spring, and then pull out the relay. Do not use excessive force or shake left and right when pulling it out, as it may damage the relay or socket.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Product electrical life

The relay contact is connected to DC24V1A resistive load; its electrical life is 1106 times


Product Introduction

JZXC-0.14 type rectifier relay is an important element in interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the way, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays.

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

The JZXC-0.14 type rectifier relay is used in the signal circuit for the filament supervision or conversion relay for the electric concentration of small stations and the local power supply in the automatic block section.



Features

1. The relay is a heavy elastic rectifier electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized.


Product Introduction

The JWJXC-135/135 stepless enhanced relay is an important element in the chain equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays.

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product function

It is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits.



Product Usage

JWJXC-135/135. Infinitely enhanced relays (hereinafter referred to as relays) are used as general relays in signal circuits.



Applicable environment

The applicable environment of the relay is:

a) Ambient temperature: -40â??~+60â??;

b) Relative humidity: not more than 90% (temperature +25�°C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Insulation withstand voltage

Under the standard atmospheric conditions of the test, the insulation resistance of the relay should not be less than 100MQ.

Under the condition that the air pressure is not lower than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz, 2000V rms voltage, there should be no breakdown flashover after 1min, the voltage when repeating the test Should be 75% of the original test voltage value.


Product Introduction

The JWJXC-160 type stepless enhanced contact relay is an important element in the interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the switch and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays.

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

The JWJXC-160 type stepless strengthened contact relay is used as a phase-failure supervision relay in the power supply screen.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.


product description

JWXC-7 type infinite relay is a relay widely used in railway signal technology, called signal relay, and it is an important part of railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

The JWXC-7 type infinite relay is used as a general purpose and air-proof step-down relay in the signal circuit.



Applicable environment

The applicable environment of the relay is:

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25);

c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



product structure

Infinite relay is the typical structure of AX series relay, which is composed of electromagnetic system and contact system. The electromagnetic system includes coils, iron cores, vehicle irons and armatures. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the yoke by a butterfly-shaped steel wire, which is flexible in movement. There is a heavy hammer in the transmission part of the Yantie to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, vehicle iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence.


Product Usage

The JYJXC-135/220 type has a pole reinforced contact relay used as a switch control relay in a signal circuit.



Applicable environment

The applicable environment of the relay is:

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Mechanical properties

Number of contact groups: 2DF, 2DFJ;

Identification pin number: 15, 54;

Contact gap: ordinary contact is not less than 4.5mm; reinforced contact is not less than 7mm;

Pallet gap: ordinary contact point is not less than 0.35mm;

Ordinary contact pressure: the positioning contact is not less than 150mN; the reverse contact is not less than 150mN;

Strengthen the contact pressure: the positioning contact is not less than 400mN; the reverse contact is not less than 400mN;

Contact uniformity error: between ordinary contacts and ordinary contacts, between ordinary contacts and reinforced contacts, no more than 0.2mm, between reinforced contacts and reinforced contacts, no more than 0.1mm.

Positioning or reverse position holding force is not less than 4N;


Product Usage

The JWJXC2-6800 type enhanced contact relay is used in the distributed power supply screen.



Product function

It is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits.



Applicable environment

The applicable environment of the relay is:

a) Ambient temperature: -40~+60

b) Relative humidity: not more than 90% (temperature +25);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



test method

Standard test conditions

Temperature: +15â??~+45â??;

Relative humidity: 45%~75%

Air pressure: 86kPa~106kPa

Requirements for testing measuring tools, meters, and power supply

The accuracy of the measuring tool for measuring appearance and installation dimensions should not be less than 0.05mm; the accuracy of the feeler gauge should not be less than level 2; the measurement error of the force measurement should not be greater than 2%.

The accuracy of the DC voltmeter and ammeter used for testing should not be less than 0.5, and the accuracy of the AC (50Hz) voltmeter and ammeter should not be less than 1.

The power supply voltage should remain stable, and its fluctuation range should not exceed 5%. The DC power supply should be a DC generator, battery or AC full-wave rectifier power supply (except for special regulations, the ripple factor should not be greater than 5%). The waveform of the AC power supply should be a sine wave with a frequency of 50 Hz.



Mechanical properties


Product Usage

The JWJXC-7200 type stepless enhanced contact relay is used as a power supply supervisory relay for the electric point machine in the power supply screen of a large station.



Product function

JWJXC-7200 type stepless enhanced contact relay is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits.



Applicable environment

The applicable environment of the relay is:

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



product structure

The electromagnetic system of the stepless strengthened contact relay is a stepless magnetic circuit with an enlarged size. The contact system is composed of two parts: a normal contact and a strong contact. The normal contact is the same as the stepless relay. Switches, switch start, etc.) designed contacts and isolator.



Mechanical properties

Number of contact groups: 4QJ; 2H

Identification pin number: 14, 55;

Strengthen the contact gap: not less than 7mm;

Ordinary contact gap: not less than 4.5mm;

Reinforce the gap of the support plate: generally not less than 0.35mm;

Reinforce the gap of the support: the reinforcement is not less than 0.1-0.3mm;


Product Introduction

JWJXC-H125/0.44 stepless enhanced contact slow release relay is an important component in interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and Close and so on. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays.

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

JW.JXC-H125/0.44. The stepless strengthened contact slow release relay is used as a general relay in the signal circuit.



Applicable environment

a) Ambient temperature: -40~+60;


Product Introduction

JMS2-110 impulse relay is suitable for AC counting track circuit as a track relay.



Applicable environment

(1) Temperature: -40~+60

(2) Relative humidity: not more than 90% (+25)

(3) Air pressure: not less than 74.8kPa (equivalent to an altitude below 2500m)

(4) Working position: horizontal

(5) Vibration: when the frame frequency is 5Hz~55Hz, there should be no resonance; when the frame frequency is 5Hz~30Hz, the amplitude is not more than 0.35mm; when the frame frequency is more than 30Hz~55Hz, the amplitude is not more than 0.12mm;

(6) Impact 40~80/time, acceleration is not more than 5g;

(7) There should be no harmful gas causing explosion hazard around, and dust-proof measures should be taken.



Model meaning


Product Introduction

JMS2-110 impulse relay is suitable for AC counting track circuit as a track relay.



Applicable environment

(1) Temperature: -40~+60

(2) Relative humidity: not more than 90% (+25)

(3) Air pressure: not less than 74.8kPa (equivalent to an altitude below 2500m)

(4) Working position: horizontal

(5) Vibration: when the frame frequency is 5Hz~55Hz, there should be no resonance; when the frame frequency is 5Hz~30Hz, the amplitude is not more than 0.35mm; when the frame frequency is more than 30Hz~55Hz, the amplitude is not more than 0.12mm;

(6) Impact 40~80/time, acceleration is not more than 5g;

(7) There should be no harmful gas causing explosion hazard around, and dust-proof measures should be taken.



Model meaning


 
 