Please click here to check who's online and chat with them.

LK Precision Medical Catheter Co., Ltd.

Supplier From China
May-26-17

Hearing Aid Tubing


Hearing Aid Tubing


Catheter tubing: Polyurethane material, good biocompatibility, fully radiopaque.

Soft tip tubing: different sizes suitable for different catheters, soft and flexible.

Catheter extension tubing: transparent polyurethane material,with tight tolerance.
Provide post extrusion services:soft tip forming, hole punching and printing.
Sizes: Single-lumen: 14G. 16G.18G.20G.
Double-lumen:4F.5F.7F.8F.


Pig tail catheter (single & double J ) , for Urology applicants.
Use polyurethane material, radiopaqued, good flexibility and memory.
Catheter automatically softens under body temperature.
Good biocompatibility, good for 90 days implant.
Sizes: 4F-8F, or customized


Rectum pressure test catheter
Urethral catheter


Smaller diameter highlights the catheter crossability.

Tapered soft-tip design reduces the risk of puncturing wall.

Securer transition design strengthens the catheter pushability
Optional-size balloon crosses various lesion
Unique lubricious coating design makes it easy to advance the balloon to the lesion.
Excellent balloon refolding and trackability allows multiple dilatation


IV catheter tubing with four to six radiopaque stripes.
Use PU or FEP material.
Ultra smooth surface with very low friction.
Sizes:14G.16G.18G.20G.22G.24G


Two types with one hole and two holes, drainage catheter.
Size from 4mm to 12mm, or customized.


The size of inner diameter and outer diameter is high precision with stable flow.
Specification supplied is 0.05mm, 0.06mm, 0.08mm, and 0.1mm.
The catheter is soft and high transparent.


Contrast media injection extension line, Pressure rated to 1200 PSI (83 BAR).
Braided with high strength fiber, and Monofilaments, good transparency.
Rotating male luer lock allows 360-degree manipulation without disconnection or tangling of the tubing lines, Rotating male connector has silicone gaskets and minimizes the possibility of trapped air in the line.
Sizes: OD3.65mm,ID1.8mm,measures in standard length of 30" (76cm), 48" (122cm) and 59" (150cm)or customized with or without Rotating male luer and female luer.


PU or PVC material
The size is high precision with excellent appearance.
Pressure rated to different grade, 300PSI, 500PSI, 900PSI, 1200 PSI


May-29-17

The size is high precision with excellent appearance.
We can supply twin catheter with two colors and colorful strips to customers or customized


Multi-lumen Tubing


Contrast media injection extension line, Pressure rated to 1200 PSI (83 BAR).
Braided with high strength fiber, and Monofilaments, good transparency.
Rotating male luer lock allows 360-degree manipulation without disconnection or tangling of the tubing lines, Rotating male connector has silicone gaskets and minimizes the possibility of trapped air in the line.
Sizes: OD3.65mm,ID1.8mm,measures in standard length of 30" (76cm), 48" (122cm) and 59" (150cm)or customized with or without Rotating male luer and female luer.


Braided reinforced tubing for angiography application.

Nylon elastomer material.
Pressure rated from 1200 to 2000 PSI.
Fine stainless steel wire braided, wire OD ranging from .0013'' to .002''.
Soft tip welding is available.
Sizes: 4Fr. 5Fr. 6Fr.


Wall thickness as thin as 0.05-0.08mm, over 95% transmittance.


Sheath tubing for introducer sheath
Occluder, vena cava filter and Stent delivery system.
Good biocompatibility, fully radiopaque with smooth tip.
Sizes: 4Fr to 15Fr.


May-27-17

Radiopaque HDPE material with different color.
Suitable for .035'' or .038'' guide wire passing through.
Very smooth surface and excellent tip configuration.
Sizes: 4Fr to 15Fr.


 
 
Contact Supplier
Renew

Verification Status