Please click here to check who's online and chat with them.

B & G Transformers

Supplier From India
Aug-18-09
Supplier : Distribution transformers, instrument transformers, HV tester, testing equipment

Established: 2009

Verification Status



Contact Details:
Kasheli, Bhiwandi
Thane 400601
Maharashtra India


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: B & G Transformers

Aug-18-09
Supplier From Thane, Maharashtra, India
 
Manufacturer of distribution transformers. Instrument transformers, hv tester, testing equipment.
Dec-02-21

Current Transformer Field Tester

$770 - $15.40K
MOQ: Not Specified
 
Product description

Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong.



Technical index

Test range: 5A5A~25000A5A or 5A1A~5000A1A

Tested current transformer work scope: 1% 120%

Second load 2.5 VA 300VA, COS 0.8 1.0

Be tested current transformer accuracy range 1.0, 0.5, 0.5 S, 0.2 and 0.2 S

Resistance, admittance measurement errors 5.0%

Measurement range R 0.00 ~20.0 Y 0.000mS~100.0 mS

Power consumption 20 VA

Accuracy level 0.05 S level

Shape dimension mm 460 L 375 W 183H

Weight kg 10



Feature

HCCT-H Current Transformer Field Tester with recursive method to measure current transformer error, as well as potential difference method to measure voltage transformer error function, convenient for carrying out calibration work of field metering device.

HCCT-H Current Transformer Field Tester without using Standard Current Transformer, Current Source, Load Box, Double Adjustable Control Box and Primary cable, using extremely simple test connection and operation to realize the current transformer test, greatly reduce work intensity and improve the work efficiency, convenient to carry out current transformer field test work.
Aug-26-22
 
Product description

The current booster is used on checking current transformer,to be the power source supply once current for current transformer or to be other 50Hz single phase current source device.



Technical index

Temperature

Humidit

Capacity: 20kVA

Specification

Weight: 75Kg

Allow long-term work on the rated current

Allowable overload 1.5 times,30 minutes of continuous work.



Feature

This PSLLQ is make up of input Winding(220V), output winding below 100A and CXRZ.

Output current indicated on the nameplate is defined the rated current that through winding allow to pass.When CX many circles, the rated current its permitted to pass through will inversely decline.

The value which ouput capcity divided by product of output current and each circle voltage was the biggest circle number allowing.



The current booster is designed to provide the primary current power supply for the current transformer when verifying the current transformer or as other 50HZ single-phase power equipment. The current booster for transformer verification is suitable for power departments such as power testing, power measurement, and power maintenance. The current booster is developed and produced according to the industry standard of transformer error testing, and is used as a current transformer to verify the primary current of the current transformer. The output current can be customized according to customer requirements. The lifter is equipped with casters for easy on-site movement.
GOLD Member
VERIFIED
Jul-12-24
Supplier From Mumbai, Maharashtra, India
GOLD Member
VERIFIED
Nov-21-20
Supplier From New Delhi, Delhi, India
GOLD Member
VERIFIED
Jun-20-25
Supplier From Howrah, West Bengal, India
Dec-24-21
 
Overview

In the process of semi finished and finished production of power transformers, before the newly installed transformers are put into operation and according to the state Grid's preventive test rules, it is required to test the transformer's turn ratio or voltage ratio regularly.The traditional variable ratio bridge operation is tedious, the reading is not intuitive, and the necessary conversion, the test result is only one phase change ratio value.The transformer transformer ratio tester overcomes the shortcomings of the traditional transformer ratio bridge test, the screen uses a large screen high resolution LCD screen, convenient to use in the field, with Chinese menu prompt function, simple and intuitive operation, a complete three phase change ratio test, test speed, high accuracy.



Technical parameter

range 0.910000
The accuracy of
reading 0.1 2 words or equal to 500

reading 0.2 2 words 500 3000

Reading 0.3 2 words 3000

The resolution of the
0.9 9.9999 0.0001 100 999.99 0.01 10000 and above 1

10 99.999 0.001 1000 9999.9 0.1

Working power supply AC220V 10 50Hz
Instrument weight 3.5kg
The use of temperature 10 50
Overall dimensions 260mm l 200mm W 160mmH
Relative humidity 90 no dew


Feature

Full three phase sinusoidal inverter output, the output voltage is automatically adjusted, with soft start, soft stop function, so the test speed is fast, high precision

Three-phase transformer, single-phase transformer, PT, Z type transformer ratio, group, polarity test function

Blind test function, that is, variable ratio and group test when high and low pressure connection mode is not known;

CT variable ratio polarity test function

Angle difference test function for single-phase test

Tap position can be tested up to 197
GOLD Member
Sep-04-14
Buyer From Jalandhar, Punjab, India
Mar-11-22
 
Product description

Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong.



Technical index

Verification Status