Please click here to check who's online and chat with them.

Prospect

Supplier From China
Jul-06-22
Supplier : Elevator products, such as elevator load weighing control device, energy saving device for elevators, IC card management system, elevator earthquake detector, remote supervisory management system, and other elevator parts

Services :
Established: 1999 Standards: CE

Verification Status



Contact Details:
No.3, Jinghe Street, Huashan Zhong Road, Qinhuangdao Etdz, Hebei, China
Qinhuangdao
Hebei China


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Prospect

Jul-14-22
Supplier From Qinhuangdao, Hebei, China
 
Time limited, disturbance-free, to make safer elevator
Variety ways of elevator calling like Card,code,fingerprint,phonenumber,etc.
Billing daily,monthly or in each time to make property charge easily


SYSTEM CHARACTERISTIC
The system and the elevator system are use dry contact linkage both separated
completely, non-interfering running.
The IC card can cancel control automatically which means the IC card smart
control system will automatic avoidance while switch back to IC-led control if
there have some special conditions(system outage, breakdown)

After the director finish time alignment, it will ensure the time veracity of di-
rector and no need to alignment in 5 years.

The director can save 60000 different NO.s of cards ,999 code cards 30
black lists, the record of the storage would not lost in 10 years.
Easy installation, both for the news and the olds.
Support network and non-network modes
It can combine subsystem to achieve ONE-CARD system
The elevator linkage use non-polarity field-bus system
Use kinds of communications like CAN RS485 RS232 to communicate
with elevator mainboard.




Visitor function receive visitors without stepping out

1.Code call :Integrated design with the reader \brand new touch keyboard\LCD
backlight\use simply
2.Smart call: No need wiring\especially for in-use elevator\cellphone remote
control elevator/real exclusive elevator
3.Linkage call:No puzzle about the compatibility with talkback maker, independent
running, convenient, safe and fast.
Jul-14-22

The Elevator Load Weighing Control System

$100 - $450
MOQ: Not Specified
Supplier From Qinhuangdao, Hebei, China
 
Key product in new plan
Self-learning,no debug, off line, power-off protection, bug autoalarm
Supporting more than 300 elevator manufacturing enterprises in the world

SYSTEM OVERVIEW
Prospect Elevator Load Weighing Control System is a essential system which is using
in different kinds of elevator such as passenger elevator,cargo elevator,medical use elevator staircase so that the elevator could running safely and comfortably. The system can provide not only a group of relay electric shock signal for overload, full load, half load, light load status, but also various of analog quantity signals for 0 10mA; 4 20mA;-10 10V or 0 10V.
Prospect Elevator Load Weighing Control System could provide multiplicate installation methods like rope hitch installation,car platform installation,wheel and axle installation,traction rope installation and escalator pedal bottom installation. In order to offer a safe and comfortable elevator running status.

FEATURES AND PARAMETERS ABOUT THE SENSOR
Integration structural design, CrNiMo alloy material, correspond the IP65 request, totally adapt to hi-humid environment. Overload capacity150%, line output accurate, load range for each sensor is 100kg~5000kg.

SYSTEM FEATURES
1.3-position Nixie Tube display
It could show the rated load percentage of the elevator and the storey.Use conveniently.
2.Reliable anti-jamming
The system uses optical isolation technology, non-interfering for multi-elevator running.
The door status, up direction,leveling signal are adapt to contact signal input.
Either high level or low level is OK.
3.Setting in site
Free set the rated load tonnage of elevator or read the actual weight of elevator as rated load tonnage.
4.Adjustment methods
No need for weights self-learning, full load self-loading and remote debugging facility.
5.No inertia error alarm while running
The controller detect and control output while the door open. No detect and control
while elevator rise or fall.
6.Bug self-diagnosis
When the controller or the sensor break down or in off-position, the system could output overload contact signal automatically.
7.Free adjust in site
Adjust system in 1:1 or 1:2 mode.
8.Offer various of communication interface
According to need, CAN or 485 and other kinds of communication interface could be
provided to system.
9.Sensors in free match
You can free match diversified sensors from our company and connect 12 sensors through sensor expand module.

OPTIONAL FUNCTIONS
1,Far-end display
Inside installation, it will show load capacity in real-time inside the elevator according to need.
2,Voice hint function
Inside installation, it will prompt load capacity by voice inside the elevator according to need
Jul-24-22

Elevator Forewarning Rescue Car

$700.00K
MOQ: Not Specified
Supplier From Qinhuangdao, Hebei, China
 
The elevator forewarning rescue car is used for rapid emergency response to elevator safety accidents. Equipped with responsive elevator hardware equipment and six types of software, it can realize emergency rescue of elevator accidents within the city.
Jul-14-22

Elevator Seismic Device

$500
MOQ: Not Specified
Supplier From Qinhuangdao, Hebei, China
 
Accurate perception of the seismic information
Avoid earthquake damage to the elevator
Timely rescue of trapped person
Participate in the State administration of quality supervision the 2008QK21
subject research
Participate in the National elevator shockproof standards drafting


SYSTEM OVERVIEW

The elevator earthquake detector is used in conjunction with the elevator control system, make the elevator before the earthquake happened or occurs effective enter into the control operation of the equipment. Before the earthquake arrival, the elevator earthquake detector early detection to seismic waves, output alarm contacts to the elevator control system, the elevator control system according to the contacts state in the recent floor flat layer to open the door, release the passengers out of the elevator, the maximum save the life safety of the passengers, ensure that the elevator equipment is not compromised.


FEATURES AND PARAMETERS
Input voltage:AC220 10% 50 Hz 60 Hz

Output way:2 relay output

Contacts capacity:1.0 A 30 V DC, 0.5 A 125 V AC

Frequency response:0.1 Hz 30 Hz

Level 1 alarm acceleration threshold set range:0.2 m/s 1m/s

Level 2 alarm acceleration threshold set range:0.4 m/s
Acquisition accuracy:0.01m/s

Reset way:manual reset

Alarm record:100 strips

Overall Power Consumption: 1 W

Weight:1kg



SYSTEM PRINCIPLE

Product collection when the earthquake ground X/Y/Z three of the direction of ground motion acceleration, accurate detection of the earthquake happened, when P wave arrived acceleration sensor detected early earthquake of vertical vibration then output corresponding electric signals, through the filter and amplification by Analog to Digital Converter for microprocessor processed. When S wave arrival, acceleration sensors to detect the horizontal vibration, and output corresponding electric signals, through the filter and amplification by Analog to Digital Converter for microprocessor processed.

The instrument has two road relay output, respectively is level 1 alarm output, level 2 alarm output, access the elevator control system respectively, for the elevator control system collection. Level 1 alarm output is instruments detected early earthquake P wave or low vibration acceleration of earthquake movement after output, is a low-level output, used to judge may be happen earthquake, after Level 1 alarm relay action, if in 10s inside not have to achieve the Level 2 alarm ground vibration signal, the product to be automatic reset, and contacts signals disappear. Level 2 alarm output corresponding higher ground motion of the output of the acceleration, can't automatic reset, and need professional elevator operator to inspection elevator, and after confirm the elevator without any fault then manually reset.


FUNCTION CHARACTERISTICS
Jul-14-22

Elevator Braking Ability Detector

$200
MOQ: Not Specified
Supplier From Qinhuangdao, Hebei, China
 
BC100 traction drive elevator brake capability detector is a kind of equipment to detect if the traction elevator braking capacity is qualified .
GOLD Member
Jun-07-21
 
Model Number:
Portable Air Conditioner ((WT-F26 gray)
Power Type: DC
Use: Room
Condition: New
After-sales Service Provided: None
Warranty:1 year
Type: PORTABLE
Certification:CB, ce
Cooling/Heating:Cooling Only
Application:Car, Commercial, Garage, Hotel, Household, Outdoor, RV
Power Source:Electric, usb
Remote Control: Yes
App-Controlled: Yes
Mar-31-11

Elevator Landing Door Device

$104
MOQ: Not Specified
 
We are a company in Shaanxi province provide all series elevator parts such as PCB, Comb plate, guide rail, guide shoe, buttom, swith, oil can, door vane, wheel etc for Fuji, Selcom, LG-OTIS, KONE, SCHINDLER, MITSUBISHI and other famous brand.
VERIFIED
Jun-05-21
 
* PHOSCAST
Phoscast : Phosphate Bonded Castables

* PURPOSE
customers using FBC boilers (Particularly underbed feed FBC boilers) for the protection of inbed coils against erosion potential by applying highly abrasive resistant refractory on inbed coils above fuel feed system.

BACKGROUND

* Two of such actions are providing special alloy studs on inbed coils and applying highly abrasive resistant refractory on the outer bottom loops of inbed Coils which are above the fuel feed nozzles.

* GANESHAS has taken number of approaches to identify the key factors affecting erosion rates with an objective to enhance the life of inbed tubes as well as implementing the corrective action to reduce the erosion rates.
Phosphate coatings are often used to protect steel parts against rusting and other types of corrosion

* Erosion of inbed coils in fluid bed combustor is unavoidable phenomenon however the rate of metal wastage and thus the life of tubes depends on various factors like ash & fuel properties, design of Combustor / feeding system, flue gas velocities operating conditions etc. It has been also observed that maximum erosion prone inbed coils are those which come above fuel feed nozzles and an area of approximately 1 to 1.5 mts around fuel feed systems are badly affected.

APPLICATION
Phoscast-90 XR can be applied by ramming with wooden mallet having adequately large head @" dia x 5" length x 10â?? Jong handle). The desired lining or repair thickness is built up in several courses while ramming the mass to uniform thickness. Phoscast refractory should never be trawled to obtain smooth surface; ramming only should finish surface. Any excess mass is to be sliced off with trowel edge and then finished by ramming again for bed coil. Tube application of AFBC boiler, the material pasty mass should be finger pressed into the studs of the tube with maximum force. Finish should be given by pressing the hand palm against material applied, using surgical type thin rubber hand gloves.
VERIFIED
Nov-14-16

Root Elevator

$3.50
MOQ: Not Specified
Supplier From Sialkot, Punjab, Pakistan
 
Root elevator for all pattern

Verification Status