Fire extinguisher, portable or movable apparatus used to put out a small fire by directing onto it a substance that cools the burning material, deprives the flame of oxygen, or interferes with the chemical reactions occurring in the flame. .
"Product name
Fire Extinguisher Cylinder
Type
0.5kg/0.8kg/1.2kg/1.3kg/1.35kg/Cutomized
Material
Steel
Usage
CO2 Fire Fighring
Keywords
Co2 Fire Extinguisher
Color
Customer Request
Working pressure
150bar"
Our fire extinguishers are designed for maximum safety and efficiency, suitable for homes, offices, and industrial use. Available in various types and capacities, they provide reliable fire protection for different hazards.
"Total Weight - 1.3 KG
Diameter - 146mm
Activation Time - Approx 10 seconds
Warning Sound - 120 - 140 dBA
Fire Extinguish for an area - 3 Cubic Meters"
Key Specifications :
Work on all types of fire
Automatically activates upon contact with flames
Simple to use, no training required
Ideal for homes, offices, hotel, industrial settings
provides fast and reliable fire safety
No maintenance cost required for Agni Kawach fire extinguisher ball."
The FK-5-1-12 Clean Agents, also known as NOVEC1230 Fire Suppression Agents, is a highly efficient and reliable hydro-fluorocarbon fire extinguishing solution. This product is designed to quickly and effectively suppress fires in various settings while being non-toxic, environmentally friendly, and safe to use.
Model Number: FK-5-1-12 clean agents
Product Name: NOVEC1230 Fire Suppression Agents
Reliability: High
Model NO.: FK-5-1-12 clean agents
Application
The FK-5-1-12 Clean Agents is suitable for use in various applications, including but not limited to:
Commercial buildings
Industrial facilities
Data centers
Telecommunication rooms
Museums and art galleries
Power generation plants
Server rooms
Control rooms
Storage facilities
The Notifier NBG-12 Series Pull Station is a fire alarm initiation device that allows manual activation of the fire alarm system. It typically consists of a red or yellow manual-pull handle or lever, which when activated, sends a signal to the fire alarm control panel to initiate an alarm. The NBG-12 series is designed for use in fire alarm systems and is commonly used in commercial, industrial, and residential buildings. The product is known for its durability and reliability, and it meets industry standards for fire alarm systems.
Intelligent fire Detection system as a high efficiency and low cost unmanned fire detection system in capable of an early detection regardless spontaneously fire or firebug.
This system is located in outdoor area such small and middle sized cultureal assets, natural monument and outdoor facilities.
DESCRIPTION
Introductions:
1.firefighting equipment Approval:ABS,CCS,BV,DNVetc
2.fire fighting equipment material :stainless steel
3.Capacity of fire monitor/fire pump : 160m3/h,180m3/h ,360m3/h ,600m3/h , 900m3/h , 1200m3/h , 3600m3/h ,etc
4.firefighting equipment Type:Supply external Fire Fighting Systems , FiFi1/4,FiFi1/2, FiFi 1, FiFi 2 , etc
5.Fire Fighting System Engine:Cummins Engine or the demands you need
6.Fire fighting equipment Include:fire pump,fire monitor,with diesel Engine
7.Firefighting equipment color:red
Technical Parameters for Maritime Fire Fighting Fifi 3/ Firefighting 1 And 2 Firefighting Class System.
1.FiFi Class 2 System 7200m3/h
Diesel Engine Driven
Fire Pumps: 2X3600m3/h
Fire Monitors:4X1800m3/h@150m,
Remote Control System
2.FiFi Class 1 System 2400m3/h
Diesel Engine Drivenor Electric Motor Driven
Fire Pumps: 2X1200m3/h or one 2400m3/h
Fire Monitors:2X1200m3/h@120m
Remote Control System
3..FiFi 1/2 System
Diesel Engine Driven or Electric Motor Driven
Fire pumps: 1200m3/h
Fire Monitors:2X600m3/h@120m or1X1200m3/h@120m
Remote Control System
4.None Classed Fi-Fi System
Diesel Engine Drivenor Electric Motor Driven
Fire pumps:2X300m3/h@145m
Fire Monitors:2X300m3/h@85m
5. None Classed Fi-Fi System
6.Fire Pump Unit, fire pumpCapacity: 4200m3/h,3600 m3/h, 2400 m 3/h, 1800 m3/h, 1200 m3/h, 600 m3/h, 300 m3/h,250 m3/h ,ect
Certificate: CCS BV ABS DNV and other Class
7. Fire monitor
Including fire water monitor , foam monitor , powder monitor with Electric/hydraulic romote control and hand whell
REMARK:Designated the best solution for you,according to your requirements. Above just for your guidence.
If you need this products For ship,pls provide the below information for external Fire Fighting Systems
1. Capacity of the Fire monitor for this Fire Fighting Systems (m3/h)
2. Fire pump Capacity for Fire Fighting Systems(m3/h)
3.Need the diesel Engine for fire pump
4.Any special brand demands for diesel fire pump engine
Related pictures Maritime Fire Fighting Fifi 3/ Firefighting 1 And 2fir Firefighting Class System(fire monitor,fire pump,diesel engine for firefighting equipment)
DESCRIPTION
Type: PP24C
Service Pressure: 0.5-1.0MPa
Max Service Pressure: 1.0mpa
Spray Capacity: mixed liquids 24l/s, water24l/s
Range: more than 40m
Horizontal rotary: more than +- 180degrees
Max angle of elevation: more than +- 70 degrees
Max angle of depression: less than -60degrees
Allowable error of discharge capacity: +- 8%
Foaming times(at 20degree): more than 6
25% discharge time(at 20 degree): more than 2.5min
Effluent capacity: 85T/H
Connection Flang: DN80