Please click here to check who's online and chat with them.

Ptek SRL

Supplier From Italy
Oct-01-14
Supplier : Battery charger, battery charger, repellent device

Established: 2013

Verification Status



Contact Details:
Via Tazio Nuvolari, 5
Misano Adriatico 47843
Italy


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Ptek SRL

Oct-07-14
Supplier From Misano Adriatico, Italy
 
Charge end, duration of equalized charging phase:
Each hour 5’ (repeated for 48 hours), calculation to
Determine the size of suitable battery charge: 16a
For every 100 ah of the battery (e.G. 500 ah battery:
16ax5 = 80a).
Oct-07-14
Supplier From Misano Adriatico, Italy
 
Suitable for cyclic recharge of lead – acid
Batteries and floating of sealed gel and /
Or lead - acid batteries, high frequency
Technology, compact design, protected
From wrong polarity and short circuit
Proof, feeding 110/240v.
Ip-66 degree (no ingress of dust;
Complete protection against contact -
Dust tight, water projected in powerful
Jets (12.5 mm nozzle) against the
Enclosure from any direction shall have
No harmful effects).
Oct-07-14

Ptek_Hb1

MOQ: Not Specified
Supplier From Misano Adriatico, Italy
 
Advantages of hf technology:
Optimal availability for use and long
Service life can only be achieved from
Motive power batteries when the battery
And the charger are perfectly matched.
The hf technology provides:
Compact wall-mounted designs to save
Floor space. Significantly higher electrical
Performances. Shorter recharge time,
Saving energy, reduction of the batteries
Temperature during the cycle, strong
Reduction of the co2 emissions, lower
Water consumption, which helps prolong
The life of the batteries. High production
Yield. Soft start mode, customized
Charge curve on request. Black hawk is a
Versatile device, different charging curve
Software could be installed for a specific
Customized charging profile for any type
Of battery.
Usage: suitable for the cyclic recharge
Of lead - acid batteries and floating of
Sealed gel and / or lead - acid batteries.
Optional air pump available
Download data available
Trough pc/laptop.
230 vca ± 10%, mono-phase, input frequency 50 – 60 hz, efficiency ~ 90%,
Operating temperature from– 20 to + 45 °c, current drawn by the battery 0
A if network electrically bonded, protection against output short-circuit with
Fuse, protection against polarity reversal with
Fuse, thermal protection semi-conductors, input
Protection with fuses and varistors, charge curve
Programming and settings at will with default iu
Ia, displaying and messages with monochromatic
2x20 lcd display – led, audible alarm device,
State charge indicator multicolours, thermal
Compensation with optional probe, 2 auxiliary
Contacts optional configuration at will (mains
Presence, finished charge, control pump, etc…),
Ventilation forced air circulation, metallic ontainer
With dimensions 490 x 360 x 150 mm, weight
11 kg, protection ip20, in conformity with the
Low voltage directive 73/23/cee and the emc
Directive 89/336/cee and their successive
Amendments.
Oct-07-14
Supplier From Misano Adriatico, Italy
 
Over voltages, polarity reversal, anomalies.
Error code of any anomaly, inner self ventilation
Through forced air, efficiency > 85%, mass-produced
Mains leads, input cable, connection to the battery
Through anderson-rema power terminals.

Nfm
Switching battery charger, high frequency technology,
Fully controlled by microprocessor.
240v single-phase +- 10%, luminous display for a
Easy reading of the charging parameters.
Different charging curves in accordance with the kind
Of battery and choose among 16 standard curves,
Preprogrammed valid for pb-acid, gel.
Battery voltage and charge current can be changed
Through the button in the front panel.
“soft start” mode and display of the charging cycle
With led .
Electronic protection and/or fuse against short circuits
Over voltages, polarity reversal, anomalies.
Error code of any anomaly, inner self ventilation
Through forced air, efficiency > 85%, mass-produced
Mains leads, input cable, connection to the battery
Through anderson-rema power terminals.

Nfc
Switching battery charger, high frequency technology,
Fully controlled by microprocessor.
240v single-phase +- 10%, luminous display for a
Easy reading of the charging parameters.
Different charging curves in accordance with the kind
Of battery and choose among 16 standard curves,
Preprogrammed valid for pb-acid, gel.
Battery voltage and charge current can be changed
Through the button in the front panel.
“soft start” mode and display of the charging cycle
With led .
Electronic protection and/or fuse against short circuits
Over voltages, polarity reversal, anomalies.
Error code of any anomaly, inner self ventilation
Through forced air, efficiency > 85%, error code
Display missing, mass-produced input network cable,
Output cables polarized.
Oct-07-14

Ptek_Ts1

MOQ: Not Specified
Supplier From Misano Adriatico, Italy
 
With decreasing
Current (wa characteristic): 9÷11 h charging time, transformer thermal protection,
Modular installation on galvanized steel base (20/10) – (30/10), sheet steel case
With modular panels (10/10 - 12/10) - (12/10 – 15/10), epoxy powder coating, ovenbaked,
Standard colour: ral 2002 red, option: custom-made colour, logo and silkscreen
Printing, mains input and d.C. Output polarized cables, complete with mains
And battery cables; assembly of plugs and battery connectors on request.
“wa” characteristic (din 41774):
Charge at decreasing current with intervention of the final charge at
2.40 v/cell., final charge with timed control 9h / 11h, fixed charging
Time (equalization charge excluded), equalization charge (week-end
Charge) to be recalled. It will start after 55’ from charge end, duration
Of equalized charging phase: each hour 5’ (repeated for 48 hours),
Calculation to determine the size of suitable battery charge: 16a for
Every 100 ah of the battery (e.G. 500 ah battery: 16ax5 = 80a).
Oct-07-14

Ptek_Tc3

MOQ: Not Specified
Supplier From Misano Adriatico, Italy
 
Ptek tc3 three phase is designed to recharge medium - large capacity traction and
Start lead-acid batteries, developed using our forty-year experience in the field of
, three-phase rectifier
Bridge with silicon diodes, natural cooling, with snubber protection, mains input and
D.C. Output polarized cables, modular installation on galvanized steel base, sheet
Steel case with modular panels so as to assure maximum accessibility in case of
Service, epoxy powder coating, oven-baked, standard colour: ral 2002 red, new
Lexan plate with charging data very easy to understand, equalized recall push
Button, on - off push button, option to adjust the charging time from 90 to 210
Minutes, option to adjust the threshold voltage from 2.3 to 2.4 v/cell., equalization
Charge timed, led signaling charging phases or result, short check of functions and
Times, option to program the equalized charge automatically, lab-tested electronic
Circuit conforming to the directive on electromagnetic compatibility and ce marking,
Automatic disconnection of battery charger due to battery disconnection, option:
Custom-made color, logo and silk-screen printing, option: assembly of plugs and
Battery connectors on request.
Charge at decreasing current with intervention of the final charge
At 2.40 v/cell, final charge with timed control 9h / 11h, fixed
Charging time (equalization charge excluded), equalization
Charge (week-end charge) to be recalled. It will start after 55’
From charge end, duration of equalized charging phase: each
Hour 5’ (repeated for 48 hours), calculation to determine the size
Of suitable battery charge: 16a for every 100 ah of the battery
(e.G. 500 ah battery: 16ax5 = 80a).
Oct-07-14

Ptek_Td3

MOQ: Not Specified
Supplier From Misano Adriatico, Italy
 
Attery charger due to battery
Disconnection, smart charging system according to the discharge level of the battery,
Short check of functions and times, option: custom-made colour and custom-made
Logo and silk-screen printing, final acceptance test conforming to safety regulations,
Charging with decreasing current (wa characteristic): 9÷11 h charging time, charging
With decreasing current (wo - wa characteristic): 7÷8 h charging time, complete
With mains and battery cables; assembly of plugs and battery connectors on request.
Wa (din 41774):
Charge at decreasing current with intervention of the
Final charge at 2.40 v/cell, final charge with timed
Control 9h / 11h, fixed charging time (equalization
Charge excluded), equalization charge (week-end
Charge) to be recalled. It will start after 55’ from
Charge end, duration of equalized charging phase:
Each hour 5’ (repeated for 48 hours), calculation to
Determine the size of suitable battery charge: 16a
For every 100 ah of the battery (e.G. 500 ah battery:
16ax5 = 80a).

Wo-wa:
Charge at decreasing current with intervention of the
Final charge at 2.42 v/cell, final charge with timed
Control 7h / 8h, fixed charging time (equalization
Charge excluded), equalization charge (week-end
Oct-07-14

Ptek_Ts3

MOQ: Not Specified
Supplier From Misano Adriatico, Italy
 
ier output, rectifier bridge
with snubber protection, short check of functions and times, option to program
the equalized charge automatically, lab tested electronic circuit conforming to
the directive on electromagnetic compatibility and CE marking, automatic Start,
automatic disconnection of battery charger due to battery disconnection, equalization
charge based on time, charging with decreasing current (Wa characteristic): 9÷11
h charging time, transformer thermal protection, modular installation on galvanized
steel base (20/10) – (30/10), sheet steel case with modular panels (10/10 - 12/10)
- (12/10 – 15/10), epoxy powder coating, oven-baked, standard colour: RAL 2002
red, option: custom-made colour, logo and silk-screen printing, mains input and d.c.
output polarized cables, complete with mains and battery cables; assembly of plugs
and battery connectors on request.

“WA” CHARACTERISTIC (DIN 41774):
charge at decreasing current with intervention of the final charge at
2.40 V/cell., final charge with timed control 9h / 11h, fixed charging
time (equalization charge excluded), equalization charge (week-end
charge) to be recalled. It will start after 55’ from charge end, duration
of equalized charging phase: each hour 5’ (repeated for 48 hours),
calculation to determine the size of suitable battery charge: 16A for
every 100 Ah of the battery (e.g. 500 Ah battery: 16Ax5 = 80A).
Oct-07-14
Supplier From Misano Adriatico, Italy
 
10v and/or 220v as default.
Each ptek rvhf battery charger is equipped with external aluminium cover box,
Input cable and battery cables (for small one equipped with a fast connection
Crocodile).
Switching battery charger high frequency technology, feeding 100 ÷ 240v singlephase
+- 10%, digital display only for d version, different charging curves selectable
For pb-acid, gel, “soft start” mode, electronic protection and/or fuse against short
Circuits over voltages, polarity reversal or anomalies, input cable, connection of the
Battery included, inner self contained ventilation through forced air, efficiency >
85%, mass-produced mains leads.
Oct-07-14

Ptek_Tc1

MOQ: Not Specified
Supplier From Misano Adriatico, Italy
 
r control is designed to
Optimize the charging cycles for any type of battery, 230v coil single-pole contactor,
D.C. Fuse on rectifier output, delta-star stray flux single-phase power transformer
Class h; impregnated in autoclave with ecological epoxy resins, with thermocouples
For disconnection due to maximum temperature, single-phase rectifier bridge with
Silicon diodes, natural cooling, with snubber protection, mains input and d.C. Output
Polarized cables, modular installation on galvanized steel base, sheet steel case with
Modular panels so as to assure maximum accessibility in case of service, epoxy
Powder coating, oven-baked, standard colour: ral 2002 red, new lexan plate with
Charging data very easy to understand, equalized recall push button, on - off push
Button, option to adjust the charging time from 90 to 210 minutes, option to adjust
The threshold voltage from 2.3 to 2.4 v/cell., equalization charge timed, led signaling
Charging phases or result, short check of functions and times, option to program
The equalized charge automatically, lab-tested electronic circuit conforming to the
Directive on electromagnetic compatibility and ce marking, automatic disconnection
Of battery charger due to battery disconnection, option: custom-made color, logo and
Silk-screen printing, option: assembly of plugs and battery connectors on request.

Verification Status