The NFS-3030 is a fire alarm control panel (FACP) manufactured by Notifier. It is designed for use in small to medium-sized fire protection systems and provides effective fire detection and alarm notification. The NFS-3030 features a compact design and advanced microprocessor technology, making it easy to install and program. The control panel supports up to 384 points and includes built-in communication options, such as analog dialer and network interfaces, for remote access and system integration. It is compatible with a range of Notifier fire detectors, modules, and accessories, providing versatility and customization for specific fire protection needs. The NFS-3030 is a cost-effective and reliable fire alarm control panel from Notifier.
The NFS2-640 is a fire alarm control panel (FACP) manufactured by Notifier. It is designed for use in medium to large-scale fire protection systems and provides reliable fire detection and alarm notification. The NFS2-640 features a compact design and advanced microprocessor technology, allowing for easy installation and programming. The control panel supports up to 640 points and includes built-in networking capabilities for remote access and system integration. It is compatible with a range of Notifier fire detectors, modules, and accessories, offering flexibility and customization for specific fire protection needs. The NFS2-640 is a feature-rich and reliable fire alarm control panel from Notifier.
"Product name
Fire Extinguisher Cylinder
Type
0.5kg/0.8kg/1.2kg/1.3kg/1.35kg/Cutomized
Material
Steel
Usage
CO2 Fire Fighring
Keywords
Co2 Fire Extinguisher
Color
Customer Request
Working pressure
150bar"
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be
Connected to non-addressable devices when used with addressable input modules.
Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile
Cause-and-effect pc-based programming tool enables rapid customization with software for sites that require
Special operating features.
The 6001 comes standard with features that allows flexibility and expandability.
Single loop or 2-loop options available
Single loop, expandable to 2-loops available
Networkable, up to 4 control panels
Up to 125 addressable devices per loop
Automatic device detection on start-up
Automatic device type-code verification
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
Backlit lcd display providing 4 rows of 40 characters
16 zone fire alarm led indicators
3000 event history log