AR solar glass is a kind of low iron solar glass by adding AR Anti-Reflective film coated on it. Through this film, we can get higher light transmittance and lower light reflectance. It can effectively reduce solar reflectance, thereby improves the solar ratio, ultimately improves solar generating capacity. Regular glass without coating transmits about 91% of the light through it, with about 8%of the light reflecting back(the rest is absorbed). Coating the outer surface of the glass can reduce the amount of light reflecting from 8% to 1%or 2%.
Advantages
-High solar energy transmittance and low light reflectance
- Absorb solar energy
- Texture pattern can prevent a clear perspective and protect the privacy
- Scratch-resistance
- High chemical resistance
Applications
AR solar glass is often used in the manufacturing of solar glass curtain walls, solar glass roofs, photovoltaic solar cells, solar water heater, picture frames, LED products, TV screens, and so on.
Specifications
Thickness:3.2mm, 4mm
Sizes: As per client's request.
Type of glass: AR clear solar glass, AR low iron solar glass, AR low iron patterned solar glass, tempered AR solar glass
Hollow Solar Power Glass
Construction Curtain Wall
Casement Window
Skylight
Transmittance Adjustable from 20%-60% M
Sound & Thermal Insulation
1600*1200mm
30pieces per pallet
57.6 M2 / pallet
18pallets/40ft container
Price List
Black USD85/M2
White USD135/M2
Colorful USD 338/M2
Shipping Terms: EXW
Category model
FY166M370-60
60 version (9BB-166)
Standard test conditionsï¼?AM1.5,E=1000W/m2ï¼?TC=25â??
Pmax 370W
Maximum system voltage 1500V
Tolerance range 0~5W
Maximum system current 20A
Vpm 34.0V
Operating temperature ï¼?40~85â??
Ipm 10.89A
Cell type Monocrystalline silicon
Voc 41.2V
Weight (Kg) 22kg
Isc 11.41A
Specification (mm) 1785*1046*5.3
Half-cell battery technology, brand new circuit design.
Super frame, can bear 5400Pa mechanical load test.
Drainage system design to prevent deformation and cracking of the frame due to freezing.
Significantly reduce the risk of hot spots and reduce power loss.
Excellent anti-PID performance and strict quality control ensure the high reliability of the product.
Double Glass 20A Solar Module
Category model FY166M440-72
72 version (9BB-166)
Standard test conditionsï¼?AM1.5,E=1000W/m2ï¼?TC=25â??
Pmax 440W~450W
Maximum system voltage 1500V
Tolerance range 0~5W
Maximum system current 20A
Vpm 41.2V Operating temperature ï¼?40~85â??
Ipm 10.7A Cell type Monocrystalline silicon
Voc 49.3V Weight (Kg) 25.2kg
Isc 11.2A Specification (mm) 2089*1033*5.3
Half-cell battery technology, brand new circuit design.
Super frame, can bear 5400Pa mechanical load test.
Drainage system design to prevent deformation and cracking of the frame due to freezing.
Significantly reduce the risk of hot spots and reduce power loss.
Excellent anti-PID performance and strict quality control ensure the high reliability of the product
Half-cell battery technology, brand new circuit design.
Superframe can bear 5400Pa mechanical load test.
Drainage system design to prevent deformation and cracking of the frame due to freezing.
Significantly reduce the risk of hot spots and reduce power loss.
Excellent anti-PID performance and strict quality control ensure the high reliability of the product.
View video
Share: Contact now Ask a question
Super Heat-Conducting Tube is consists of the glass tube and copper pipe. The temperature can be more 300 in the tube.
Features:
1) High heat effectiveness: higher than all glass evacuated solar collector tube by 15%.
2) heat pipes conduction: successfully prevents the defects of tube breakage and low power output caused by water fouling and deposits or dust and sand.
3) Prevents the tube from being easily broken caused by volume expansion when water freezes in the frigid season.
4) Low thermal capacity makes the tube start up quickly.
5) Energy output of sunshine within only 2 minutes.
6) Insulation temperature can reach 250, average heat efficiency can still be more than 50%; even under -50.
7) High efficient selective absorptive coatings and vacuum heat insulation technology ensure the tube has higher heat output in cloudy weather and in moist areas, especially in winter.
8) Solar collecting plate is sealed inside a high quality borosilicate glass tube with 5 x 10 - 3Pa of vacuum, to stop corrosion; even in moist conditions.
Metal-glass evacuated solar collector tube consists of a single glass tube and a flat or curved aluminum plate inside attached to a copper heat pipe.
1.All Glass Vacuated Tube
All glass evacuated tubes are the key component of solar collectors. The evacuated tube is similar to a conventional Dewar flask and consists of two borosilicate glass tubes, a glass with high chemical and thermal shock resistance. The outer side of the inner tube is coated with a sputtered solar selective surface. This coated inner tube is closed at one end and sealed at the other end to the outer tube. The annular space between the outer tube and inner tube is evacuated to virtually eliminate heat loss by conduction and convection.
We use the tubes which use the successfully developed innovative Advanced Solar Selective Coatings in commercial scale, which achieve the highest thermal efficiency and good thermal stability. Solar selective coatings absorb most solar radiation while simultaneously suppressing the thermal emittance loss from coating surfaces. They vary mainly in their optical property and thermal stability.
Excellent results have been obtained by using DC magnetron sputtering technology. A solar absorbance of 0.94 - 0.96 with an emittance of 0.04 - 0.06 at 100 centigrade has been achieved.