Name: Integral Steam Turbine Water Lubricated Pump(Energy Recovery-Turbine Pumps )
DESCRIPTION:
The Pump is a single wheel steam turbine, two-stage pump, where both the turbine and impellers are mounted on a rigid shaft, supported by a central bearing assembly integral within a monobloc turbine/pump casing.
This compact proven design will withstand water slugs in the steam line.
It requires no external services or electrical supplies to operate and is one fifth the size of a conventional pump and turbine unit. The range is designed to ASME III Class 2 or 3 requirements.
OPERATING LIMITS:
Capacity up to 1550 m³ /h
Head up to 4265m
Discharge flange size 6 to 16 in Speeds 7500rpm
Temperature up to 250°C
APPLICATIONS:
Auxiliary feedwater
Reactor core isolation cooling Boiler feed
Marine feed
Safety related applications
Name: Integral Steam Turbine Water Lubricated Pump(Energy Recovery-Turbine Pumps )
DESCRIPTION:
The Pump is a single wheel steam turbine, two-stage pump, where both the turbine and impellers are mounted on a rigid shaft, supported by a central bearing assembly integral within a monobloc turbine/pump casing.
This compact proven design will withstand water slugs in the steam line.
It requires no external services or electrical supplies to operate and is one fifth the size of a conventional pump and turbine unit. The range is designed to ASME III Class 2 or 3 requirements.
OPERATING LIMITS:
Capacity up to 1550 m³ /h
Head up to 4265m
Discharge flange size 6 to 16 in Speeds 7500rpm
Temperature up to 250°C
APPLICATIONS:
Auxiliary feedwater
Reactor core isolation cooling Boiler feed
Marine feed
Safety related applications
Water flow monitor LJZ-2 turbine parts
Selection of advanced technology, absolutely first-class service quality, YOYIK over the years to the same faith. The main technical backbone are retired senior engineer, senior mechanic. Many of them have participated in the planning, production and installation of power stations such as Gezhouba, Ertan and Three Gorges, and provided high-quality equipment selection, construction planning, installation and dispensing of hundreds of hydropower stations and overhaul of thermal power plants. , After-sales service and other train services.
Yoyik can offer many spare parts for power plants as below:
#DF-Water flow monitor LJZ-2 turbine parts-DF
Integrator Analog Input Board 421400688
Bolt electric heating rod ZJ-20-25
Eddy Current Signal Converter CON021/914-080
Speed sensor CS-1G-G-080-05-00
240v pressure switch BPSN4KB25XFSP12
Eddy Current Sensor PR6424/004-010
Speed sensor CS-1G-D-100-03-01
LVDT Sensor HBTD-6-800
Sensor DF310580-50-07-00
optical tachometer sensor SZCB-01
Casing Expansion Monitor DF9032 Max A
Heat Expansion Transducer TD-2, RANGE: 50mm
Power unit FDPC75C3-B
linear differential sensor (Linear variable differential transformer) cá»§a van MSV 1000TD
Equivalent Expanda Cable Coil for soot blower IK-530EL
LVDT Sensor HY-6-100-15-D
Heating rod DJ-18
Inverter AAD03020DKT01
Pressure relief valve YSF16-70/130KKJ
tws proximity sensor CWY-DO-810800-50-09-02-01
linear sensor TDZ-1B-05
electromechanical pressure switch BPSN4KB25XFSP19
linear position control HL-3-250-15
Speed sensor CS-1G-D-065-02-00
Heat Expansion Sensor & Transmitter TD-2 0-50mm
Switch 162F1300
Speed sensor CS-1G-G-080-03-01
Anti-interference relay UEG/F-8DPDT
POSITIONER VALVE V18345-1010521001
INTERFACE BOARD EPSUPER-JKB-090214-A
Speed probe CS-3F-M16
Bolt electric heating rod ZJ-22-5
Limit Switch WLGCA2-2-TH
LVDT Sensor TD-1-0300-15-01
Bolt electric heating rod ZJ-20-39A
Solenoid Valve 2W-160-15
Water flow monitor LJZ-2 turbine parts
Now, we design a special controller for heating water directly.
The controller should be powered by two pcs 12v/3.5ah batteries. The controller will charge the batteries automatically when the wind turbine spins.
The output voltage range of controller is made to be 110~240vdc.
Before 110vdc, the controller is disconnected with water heating resistors. The wind turbine is spinning without loads.
Within 110~240v, the output voltage of controller is connected with water heating resistor automatically. The water heating resistor starts to heat the water. Our heating controller could increase the power flow to the heating element when the rotation speed of the wind turbine increases.
When the output voltage of controller is more than 240vdc, the dump load will consume the excess output power of wind turbine to protect the heating element against overvoltage.
High quality filter HQ25.12Z steam turbine
a strong technical force, first-class product quality, brand reputable large-scale mechanical and electrical equipment Limited. Company products covered a wide range of products sold worldwide, a number of users trust. Acting foreign first-class brand, , star, and so on products. Guarantee genuine, the spot sale.
can offer many spare parts for power plants as below:
DF-filter HQ25.12Z-DF
Separation Filter LH1201652
filter TZX2-63 10
water filter cartridge purifier KLS-50U/280
hydraulic return oil filter GLQ-100K-45T
water cleaning filter SGLGLQ-16T-50
oil filter housing HX.BH-250 5Q
water filter housing cartridge SL-31/45
EH oil pump discharge working filter V6021V4C03
filter SQCQX-25 10F10
pp micro 5 filter DLS-150
filter TZX2-25 10
oil filter elements FBX-250 10
pp filter element CYSC-1
return oil filter LH024D10BN/HC
industrial water filters DSG-125/08
hydraulic oil filter machine WY600 30Q2
pp pleated filter cartridge SL-12/50
pp filter housing SL-12/50
filter WY600 10Q2
pp water filter cartridge machine SGL-600A
best water filter SGLQ-6000A
pp water filter cartridge machine KLS-50U/280
high pressure hydraulic filter 1300R0050W/HC/B
oil press with oil filter HXW-400 100
filter SFBX-63 3
Hydraulic filter element CFF2X-520 80
filter HQ25.12Z
In a Francis turbine, the water flows radially into the turbine and axially out of the runner. The Francis turbine, invented by an American engineer in 1849, is the most widely deployed modern turbine. The main characteristics of the Francis turbine are - a wide range of water head, simple and reliable structure, and high efficiency.
A Francis Turbine can be supplied for a head of 15 m to 250 m. The runner diameter is available from 0.4 m to 4.5 m. Power capacity is from 75 kW to 50 MW.
New style francis turbine, compared to the old one, it has the advantages of convenient installation, high efficiency, low noise and compact structure.