Tube stand (xts-01)
Type : floor-to-ceiling rail
Distance of longitudinal travel : 2550mm
Distance of vertical travel : 1600mm
Rotation of x-ray tube : ±180°
Lock system : electromagnetic lock by manual
Weight : 170kg
Ceiling (xce-01, option)
Type : ceiling rail
Distance of longitudinal travel : 2800mm
Distance of vertical travel : 1200mm
Rotation of x-ray tube : ±180°
Lock system : electromagnetic lock by manual
Weight : 130kg
Bucky stand (xbs-01, option)
Type : vertical travel
Distance of vertical travel : 120mm ~ 1780mm
X-ray grid : grid ratio of 8:1, 103 line/inch
Front plate to film distance : 50mm
Weight : 105kg
4way type bucky table (xbt4-01)
Type : 4way travel
Longitudinal distance of tabletop sliding : 420±5mm
Lateral distance of tabletop sliding : 120±5mm
Tabletop to floor distance : 665mm
X-ray grid : grid ratio of 8:1, 103line/inch
Dimensions : 2000l x 750w x 665h (mm)
Weight : 150kg
6way type bucky table (xbt6-01, option)
Type : 6way travel
Drive type : electric motor drive
X-ray grid : grid ratio of 8:1, 103line/inch
Longitudinal distance of tabletop sliding : 420±5mm
Lateral distance of tabletop sliding : 120±5mm
Vertical distance of tabletop : 300±5mm
Tabletop to floor distance : 689(880)mm
Dimensions : 2000l x 750w x 680(880)h (mm)
Weight : 170kg
High voltage cable (hvc-6/8)
Length : 6m/8m
Maximum voltage : dc 75kv
The number of core line : 3 lines
Type : Manual
Maximum field size : Less than 35cm X 35cm at SID 65cm
Minimum field size : Less than 5cm X 5cm at SID 100cm
Luminosity : More than 160Lux
Inherent filtration : 1.2mmAL
Weight : 5kg
Bucky Stand (XBS-01, Option)
Type : Vertical travel
Distance of vertical travel : 120mm ~ 1780mm
X-ray Grid : Grid ratio of 8:1, 103 Line/inch
Front plate to film distance : 50mm
Weight : 105kg
4Way type Bucky Table (XBT4-01)
Type : 4Way travel
Longitudinal distance of tabletop sliding : 420¢®¨ú5mm
Lateral distance of tabletop sliding : 120¢®¨ú5mm
Tabletop to floor distance : 665mm
X-ray Grid : Grid ratio of 8:1, 103Line/inch
Dimensions : 2000L X 750W X 665H (mm)
Weight : 150kg
6Way type Bucky Table (XBT6-01, Option)
Type : 6Way travel
Drive type : Electric motor drive
X-ray Grid : Grid ratio of 8:1, 103Line/inch
Longitudinal distance of tabletop sliding : 420¢®¨ú5mm
Lateral distance of tabletop sliding : 120¢®¨ú5mm
Vertical distance of tabletop : 300¢®¨ú5mm
Tabletop to floor distance : 689(880)mm
Dimensions : 2000L X 750W X 680(880)H (mm)
Weight : 170kg
High Voltage Cable (HVC-6/8)
Length : 6m/8m
Maximum voltage : DC 75KV
The number of core line : 3 lines
***Upgradable with High Frequency Capacitor-module (Option
100 mA, 100 KVP Mobile X-ray Machine
100mA, 100 KVP, Mobile X-ray Machine for Radiography only
Electronic Timer
Electronic Overload Protection Device
Stationary Anode X-ray Tube : BEL or Imported
Collimator
Counter Balanced Mobile Stand
Suitable for Bed Side X-rays
Key Specifications/Special Features :
BTR-M400/MW400
Mobile Digital Radiography System
Full digital x-ray detector system
Image acquisition and processing workstation
Mobile electric rack
High frequency X-RAY generator
Advanced image processing software
PLX101 Series
High Frequency Mobile X-ray Equipment
PLX101/101A/101C
Rocker safety lock design, make your operate much safer
High quality x-ray monoblock assures more details, less dose
Symmetrical adjustable collimator for accurate positioning and better exposure protection
Aviation aluminum connectors, connection reliable, more safety
Advanced dislocation braking system, flexible movement, flexible braking
Multifunctional cassette storage box design
Features
Our high frequency technology assures the best image in every operating condition
Along with reduced patient dose and extended x-ray tube life time
The generator provide the right amount of penetration, reducing exposure times and retakes.
The parameter can be adjusted by the kV and mAs. Multiple security protect function such as over-voltage, over-current.
50 preset exposure programs allow extensive possibilities to optimize the exposure and processing parameters according to your preferences.
Fault automatic protection setting and fault alarming display
Parameters are automatically storage when power cut off.
Adopt rotating beam limiting device to adjust the X-ray field and angle freely.
Adopt manual controller and remote controller to do exposure.
Optional: PLXF152 mobile table for high frequency mobile X-ray equipment.
PLX101D is equipped with built-in battery, can take 200 films when full charged.
Rocker can move up and down, automatically balance
High quality X-ray monoblock can rotate in �±90�°
Options
PLXF152 Mobile Bed For Mobile X-ray Machine
Size: 2000 X 700X 500mm
Range of grid box movement 1210mm
Size of grid box: 430X 430(17 X 17)
Bucky Stand
Height: 1770mm
Vertical movement range: 470-1470mm
Grid density: 103L/inch
Grid radio: 10:1
Focus distance: 150cm
Maximum grid box: 17X 17