Woodward Easygen 3000 XT Genset Controller, 12-24 V DC, IP Rating: IP20
Woodward Easygen 5000 XT Genset Controller, 12-24 V DC, IP Rating: IP20
Woodward raised the standard in genset paralleling control and power management system with the easYgen3000XT Series controllers. These controllers come with standardized software that is simple to configure, yet easily customized for individual applications. Enhanced connectivity enables fast and secure interfacing to other controls and communications systems while the enhanced hardware is a drop-in replacement for previous generation easYgen-3000 Series Controls.
10 To 40 Degree C Stainless Steel K Type Thermocouples, For Industrial
IN tune with diversified applications, we are engaged in offering an excellent quality K Type Thermocouples. Our offered thermocouples are manufactured with precision using advance techniques in order to meet various needs of customers. Additionally, a series of quality tests are performed by our quality controllers on these thermocouples so as to eradicate any defect from this range.
BRAND : FUJI TEMPERATURE CONTROLLER
PXF9 , PXF4, PXF5, PXF4 SOCKET TYPE ALL SERIES AVAILABLE .
Precise control:
Achieved a processing speed of 50 ms which is 10 times faster than conventional models. Reading accuracy is also improved from �±0.5% to �±0.2%*.
*Comparison under 0â??850�°C range, with RTD. See the Data Sheet for details.
Easy-to-see display
MVA LCD* which offers high contrast and wide viewing angle
Process value is displayed in white
*Minimal translucent type vertical alignment liquid crystal display
Practical options
Simple watt-hour metering function: allows you to monitor energy consumption
Operating days alarm: tells you the appropriate time for maintenance work
Most compact class in industry
36% smaller (than conventional models) and 58-mm depth shallow body helps downsize your facility
Universal input
You can use any input among RTD, thermocouples, voltage, current, and mV. The set-up for input change is very easy, only requires parameter change. This allows reduction of maintenance parts
BRAND: WEST PID TEMPERATURE CONTROLLER
WEST Controller:
Model: WEST-6100+,P6100
Model: WEST-4100+,P4100
Model: WEST-8100+,P8100
Features and Benefits:
Dual setpoints & optional remote selection
Plug-in output modules allow installing just the functions needed in
Expanded user-selectable operator modes in
User-selectable plug-and-play output cards in
Process and loop alarms in
Adjustable hysteresis in
Optional 10V SSR driver in
Improved Windows PC configuration software
Improved easy-to-use HMI
Jumperless input configuration
Auto-hardware recognition
Faster communication speeds
More security options
Backward compatible panel cutout, housing and terminal wiring capability
P6100/P6170/P8100/P4100
DEIF GENSET CONTROLLER
Automatic Genset Controller AGC-4 Mk II
The automatic genset controller AGC-4 MK II can be used as a single genset controller. Also, several AGCs can be connected in a complete power management system for synchronising projects, islanded or paralleled to the mains.
The generator controller is ideal for mission-critical applications such as hospitals and data centres, and it is capable of delivering backup power in only six seconds.
'ALSTOM' Protection Relay
MODEL NO:- P94VP16A7C0540A;
Advanced Transformer Protection, Control and Condition Monitoring Transformers are high capital cost assets in electrical power systems. Internal faults are a risk for all transformers, with short-circuits dissipating the highest localised energy. Unless cleared quickly, the possibility of rewinding will diminish and core damage may become irreparable.The MiCOM Agile P642, P643 and P645 address all these issues - preserving service life and offering fast protection for transformer faults. A transient bias technique has been included, enhancing relay stability and CT requirements. CT saturation and no gap detection techniques have been included to improve the low set differential element operating time during CT saturation where the second harmonic blocking might be asserted. An external fault detection algorithm has been incorporated to prevent the CT saturation and no gap detection from affecting the second harmonic blocking .