Please click here to check who's online and chat with them.

Sending Inquiry For: O2S-Fr-T2 Zirconium Dioxide Oxygen Sensor

Jun-02-17
Shenzhen, Nanshan, China
 
Zirconia O2 Sensors
Probe Series - Short Housing

The Probe Range of zirconium dioxide oxygen sensors are available in three lengths. Suitable for aggressive and polluted applications such as boiler exhausts. Longer probes are an ideal solution for thicker walled, insulated flue pipes.

FEATURES
* Zirconium dioxide (ZrO2) sensing elements
* Long life, non-depleting technology
* Integral heating element
* High accuracy
* Requires an external interface board to operate

BENEFITS
* No reference gas required
* No need for temperature stabilisation
* Compact enclosure

TECHNICAL SPECIFICATIONS
Heater voltage
Operating (standard response) 4V DC ± 0.1V DC (1.7A)
Standby 1.65V DC (0.7A)
Operating (fast response) 4.35V DC ± 0.1V DC (1.85A)
Standby 2V DC (0.85A)
Pump impedance at 700'C < 6kΩ
Permissible gas temperature -100'C to +250'C
Gas flow rate 0 ~ 10 m/s
Repetitive permissible acceleration 5g
Incidental permissible acceleration 30g

OUTPUT VALUES
Oxygen pressure range 2mbar ~ 3bar max
Accuracy 5mbar max
Internal operational temperature 700'C
Response time (10 - 90% step)
Standard response sensor < 15s
Fast response sensor < 4s
Warm up time (prior to sensor operation) 60s
Warm up time (from standby) 20s
Output stabilisation time ~ 180s
Please ask detailed and specific questions about Pricing, Minimum Order Quantity, Delivery Timelines etc. Detailed Messages result in prompt responses.