Accuracy & repeatability
· Accuracy: +/-0.5% of reading from 0.03ft/s to 40ft/s (0.01 to 12m/s)
· Repeatability: +/-0.15% of reading
Description
· Transit-time ultrasonic
· Clamp on transducer and insertion transducer versions
· High accuracy at low and high flows
· Bi-directional flow
· Clear, user-friendly menu selections
Fluids measured
· Water and liquids, tolerant of liquids with small amounts of air bubbles or suspended solids
Flow range
· Bi-directional flow range of 0.03ft/s to 40ft/s (0.01 to 12 m/s)
Pipe sizes from 1 to 200 inches (25 to 5000mm)
Digital communications
· RS-485, Modbus RTU
SD card
· Standard SD card
· Max record: 512 days
· Record time interval
Outputs
· OTC pulse output :0~9999 Hz
· Analog output : 4~20mA
· Max load 750Ω
Temperature
· Transmitter: -40-140F (-40-60C)
· Transducer: -40-176F (-40-80C)
Please ask detailed and specific questions about Pricing, Minimum Order Quantity, Delivery Timelines etc. Detailed Messages result in prompt responses.