XLPE Cable not only has excellent electric character, mechanical character, heat and aging-resistant character, environmental stress-resistant character and chemical corrosion- resistant character, but simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working as well.
We can produce according to GB Standard(China Standard) which is equivalent to the standard IEC60502.We can also design and manufacture special XLPE cable according to the other standards required by the clients.
Xlpe power cable is used for power transmission and distribution line with voltage rated at 35kv and below.In comparison with pvc insulated power cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.
Xlpe power cable standard:
A- iec 60502-1
Rated voltage 1 kv (umax=1.2kv) and 3 kv (umax=3.6kv)
B- iec 60502-2
Rated voltage 6 kv (umax=7.2kv) to 30 kv (umax=36kv)
C- voltage grade overstep iec60502
Rated voltage 35 kv (umax=40.5kv)
Xlpe power cable is used for power transmission and distribution line with voltage rated at 35kv and below.In comparison with pvc insulated power cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.
Xlpe power cable standard:
A- iec 60502-1
Rated voltage 1 kv (umax=1.2kv) and 3 kv (umax=3.6kv)
B- iec 60502-2
Rated voltage 6 kv (umax=7.2kv) to 30 kv (umax=36kv)
C- voltage grade overstep iec60502
Rated voltage 35 kv (umax=40.5kv)
Stranded circular compacted copper or aluminium conductors, XLPE insulated, copper tape screened, three cores assembled together with non-hygroscopic polypropylene fillers, covered with extruded bedding, armoured or unarmoured and PVC sheathed Cables comply with IEC 60502.
We are supplying wide range of XLPE insulated power cables. It is important that while placing enquiries or orders, as much information as possible shall be given to us, so that the enquiries and orders are dealt quickly and efficiently.
We are supplying wide range of XLPE insulated power cables. It is important that while placing enquiries or orders, as much information as possible shall be given to us, so that the enquiries and orders are dealt quickly and efficiently.
We are supplying wide range of XLPE insulated power cables. It is important that while placing enquiries or orders, as much information as possible shall be given to us, so that the enquiries and orders are dealt quickly and efficiently.
XLPE Insulated Power Cable
Brief introduction to XLPE insulated Power Cable
Since the 1960â??s, China has made rapid progress in its XLPE cable, replacing the oil paper insulated power cable, because of its outstanding electricity property , good overload , high voltage , large transmission capacity , light weight and laying without drop limit, vertical laying, convenient installation and operation maintenance and other strong points , XLPE cable can not only be widely used in 35 KV and below medium and Low voltage Cable scope, but also largely used in 66, 110 and 220 KV high voltage transmission lines. And , in some developed industrial countries 500 KV super-high voltage XLPE cables have been opened up..
Product Standard
Huiyou Cablefocus on Various Power Cables, Our High Voltage XLPE Cables are very popular, and Our factory cab also design and produce some XLPE Insulated Power Cable for special requirements according to clientsâ?? demand. if you are interested in our products, please contact us as soon as possible.
Property for Use
a.Max rated temperature of cable conductor is 90
b.For short circuit ( Maximum sustained time not exceeding 5s), maximum temperature of cable conductor not exceeding 250
Cable rated voltage selection :
Cable rated voltage should be suitable to the system voltage and operation conditions of used cable, expressed by U0/U(Um), all are effective value, unit is KV .