Residual Current Circuit Breaker or RCCB is basically a gadget that senses current and disengages any low voltage (uneven current) circuit whenever a fault occurs. The main purpose of installing a Residual Current Circuit Breaker fundamentally is to protect people from electric shocks or death caused by them.
Jvl22-63 i (f360) rccb
Standard:iec61008
Provides protection against earth fault/leakage current and function of isolation
Applicable to terminal and pin/fork type busbar connection
High short circuit current withstand capacity
Jovean&Rogy electrical is the specialized manufacturer of modular electric terminal devices for household and similar installations.
We selling MCB,RCBO,RCCB,Switch-disconnector,Distribution Box etc.Ourproduct passed lab.test and obtained safety approvals:CE(Europe),S(SEMKO Sweden),B(Poland),CCC(China),CB,TUV(Germany),DVE(Germany),KEMAEUR(Netheland),UL(USA),IRAM(Argentina)
contact with me for more information .
YongYi Zheng,
zhengyy(at)rogy(dot)cn
Thanks
Brands : Schnieder, Abb, Legrand, L&T, C&S, Chint, HPL, Hager, Havells, etc
Current Rating : 6A to 125A
No Of Poles : 2P, 4P
Voltage Rating : 230 - 240 VAC, 230 VAC, 240 - 415 VAC, 400 - 415 VAC , 415 V
Breaking Capacity : 6KA to 10KA
Sensitivity (mA) : 30 mA to 500mA
Buy RCCB online from India at wholesale rates. If you have been looking for Schneider, ABB, L&T, Siemens, Chint, havells, HPL, Hager etc RCCB dealers, your search ends here as you can get the best RCCB distributors in countries such as USA, UK, Australia, Sweden, Africa, Middleeast, Europe, Asia etc. You can purchase RCCB of the finest quality and rest assured to get the best in terms of both durability and performance. If you are bothered about the prices, you can be totally sure to get the best rates as brings you genuine Products.
A Circuit Breaker automatically switches off electrical circuit during abnormal condition of the network means in overload condition as well as faulty condition.
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current In: 16-63A (can be extended to 125A)
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A (can be extended to 125A)
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current : A/AC
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
F362 (RCBO) breaker electrical switch mcb rccb is in accordance with standards of IEC1108-1 and GB16916-1997,applying to the circuit of AC50/60Hz,240V single phase,415 three phases and below it for industrial
and mining enterprise,building trade,commerce and family.For the ELCB is a current-operated,
fast leakage protector of pure electromagnetic type,which can break off fault circuit rapidly in order to
We manufacture and export Residual Circuit Breaker Nylon Body to our customers from Wenzhou, Zhejiang, China. NFIN series Residual current circuit breaker (without over-current protection) is suitable for the line of AC 50/60Hz,voltage 240V(2pole)/415V(4pole),rated current up to 63A.When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, RCCB will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage.
It can be used as infrequent changeover of the line in normal situation. RCCB is applicable to industrial area, commercial area, tall building and civil house.
It complies with standard IEC/EN61008.1 and GB16916.1
An Earth Leakage circuit breaker (ELCB) (now referred to as residual current circuit breaker-RCCB) is a safety device used in electrical installation with high earth impedance to prevent shock. High Quality circuit breaker (ELCB’S) Manufacturer and Exporters provides Automatic models as well as manual models ELCB’s.
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.